Windsor 10052250 Manual De Usuario

Descargar
Página de 33
MACHINE OPERATION 
 CUTTER 24V   86039070   04/10/07 
 
3-11 
 
 
DOUBLE SCRUB 
For floors which are heavily soiled or have thick 
accumulations of floor finish may not clean 
sufficiently with one pass. In these cases it will be 
necessary to double scrub. 
To double scrub, make the first pass over the 
surface being cleaned with the squeegee up, 
vacuum off, the solution on, Aqua-Mizer removed 
and brushes down. This allows the
 solution to stay in 
contact with the soil while loosening the surface 
accumulation with the brushes. Allow time for the 
first application to stay in contact with the floor. 
Length of time between the first and second pass 
depends on amount of accumulation and the type of 
chemical being used. A second scrubbing with the 
squeegee down and again the solution and brushes 
on will further loosen soil. The additional application 
of solution will further assist the difficult cleaning job. 
 
FOR SAFETY:  When using machine, go slow on 
inclines and slippery services. 
 
EMPTYING AND CLEANING TANKS 
 
1.  Park the machine next to a floor drain.  Drain 
hose is on left rear corner of the machine. 
 
2.  Turn the machine power off and set parking 
brake, if your machine is equipped with this 
option. 
 
SOLUTION TANK 
1. 
Loosen small drain hose from the retainer, then 
lower hose in direction of the drain. 
 
 
2.  Remove the solution tank cover. 
 
3.  Flush the solution tank out with clean water and 
run several gallons of clean water through 
systems. Do not use water hotter than 140°F 
(60°C) to clean tank. Damage may occur. 
NOTE:  Never allow solution to remain in tank.  
Damage to tank, seals and valves could occur.
 
 
4.  Secure drain hose into the retainer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RECOVERY TANK 
1.  Unhook the large drain hose from the retainer. 
Unscrew the T-handle on plug enough to loosen 
plug, then lower hose in direction of the drain. 
Do not stand in front of end of hose. Recovered 
solution will come out with force. Slowly remove 
plug from drain hose. 
 
2.  Remove the recovery tank dome. Flush the 
recovery tank out with clean water. Do not use 
water hotter than 140°F (60°C) to clean tank. 
Damage may occur. 
 
3.  Clean off the float shut-off system and inspect 
for free movement of float. The float shut-off 
system is located in the rear of the recovery 
tank. 
 
4. Replace the drain plug and secure drain hose in 
bracket. 
 
5. 
If machine is to be stored, leave the recovery 
tank dome off.
 
SOLUTION 
TANK DRAIN 
RECOVERY 
TANK DRAIN 
RECOVERY 
TANK COVER 
SOLUTION 
TANK COVER