MAINTENANCE 
CUTTER 24V   86039070   04/10/07 
  4-9 
!
WARNING
 
 
6. SOLUTION 
STRAINER 
The solution strainer is located in front of the left 
front wheel. The solution strainer protects the 
solenoid valve from debris. If there is little or no 
solution flow to the ground, check the strainer for 
debris. Drain the solution tank and clean the 
solution strainer. To remove the strainer, turn the 
bottom part of the strainer counterclockwise until 
the bottom is separated. Clean out the debris 
from the wire mesh and re-assemble. Make sure 
the O-ring gasket is in place when re-assembled
 
 
7. BRUSH 
MOTOR 
 
 
Do not use a pressure washer to clean around 
the brush motors. Use tap pressure only. 
 
CHANGING BRUSH MOTORS
 
 
1.  With the scrub deck in the stored position, 
disconnect brush motor wiring connector from 
harness. 
2.  Remove shrouds from scrub deck to access and 
remove scrub brushes or pad drivers. 
3.  Remove retaining bolt, lock washer, flat washer 
and star drive from brush motor shaft. 
4.  Remove 4 brush motor mounting bolts located 
under scrub deck. 
5.  Remove brush motor.  
6.  Reverse steps to install. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
BRUSH MOTOR CARBON BRUSH 
REPLACEMENT 
 
1.  
Scribe alignment mark on motor barrel to motor 
cap. Remove two bolts. 
2.  Remove end cap from motor. 
NOTE: Motors contain two wave washers in cap. 
Do not lose these.
 
3. 
Release brush from spring tension.  Remove 
screw connecting brush wire lead to brush 
holder.  Clean brush holder to insure free 
movement. 
4. 
Retract spring and install new brush.  Install 
connector screw and lead. 
5. 
When all new brushes are installed. Place all in 
retracted position, held into brush holder by 
spring tension. 
6. 
Carefully place end cap onto bearing on motor 
shaft.  
NOTE: Use care to assure wave washer 
alignment. 
7. 
With end cap in partially installed position, 
release all brushes to contact position with 
motor commutator. 
NOTE: Failure to insure all brushes are 
released will result in motor failure. 
8. 
Reset end cap and realign with scribe marks 
on motor barrel. Reinstall the two attach bolts 
from cap into base. 
9. 
Maintain alignment between motor barrel base 
and cap.