MAINTENANCE 
CUTTER 24V   86039070   04/10/07 
  4-10 
!
WARNING
 
8. 
TRACTION MOTOR 
 
 
Do not use a pressure washer to clean around the 
motors. Use tap pressure only
 
TRACTION MOTOR CARBON BRUSH 
REPLACEMENT 
 
FOR SAFETY: Before leaving or servicing machine, 
stop on a level surface, turn off machine and remove 
key. 
 
1.  Disconnect batteries from machine. 
2.  Disconnect the electrical connection to the 
traction motor. 
3.  Remove brush cap. 
4.  Release brush from spring tension.  Remove 
screw connecting brush wire lead to brush 
holder.  Clean brush holder to insure free 
movement. 
5.  Install new brush and reinstall connecting screw 
and lead. 
6.  When all new brushes are installed. Place all in 
retracted position, held into brush holder by 
spring tension. 
7.  Carefully replace brush cap onto bearing on 
motor shaft.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
9. 
CIRCUIT BREAKERS 
Circuit breakers interrupt the flow of power in 
the event of an electrical overload.  When a 
circuit breaker is tripped, reset it by pressing 
the exposed button.  If a circuit breaker 
continues to trip, the cause of the electrical 
overload should be found and corrected. 
 
 
30 Amp.  Protects the left scrub 
brush motor. 
 
30 Amp.  Protects the right scrub 
brush motor. 
 
25 Amp.  Protects the vacuum 
motor. 
 
 
 
25 Amp.  Protects the propel  
  motor. 
 
 
3 Amp.  Protects the machine 
controls. 
 
10. BRUSH SHROUDS & BRUSH SKIRTS 
Contain the water in the shroud area.  The skirt 
will flex over uneven floors and also as the brush 
or pad wears.  As the brush wears the shrouds 
can be adjusted so that skirt does not have to flex 
so much.  
 Remove three bolts on each side that fasten the 
bracket to the cover and re-assemble in the top 
holes.  When the brushes are replaced with new 
ones move the covers back to the lower set of 