Emerson Model 1700 Manual De Usuario

Descargar
Página de 350
3.2
Default values and ranges
 to view the default values and ranges for the most commonly used
parameters.
3.3
Enable access to the off-line menu of the
display
Display (standard)
OFF-LINE MAINT
 > OFF-LINE CONFG > DISPLAY
Chinese-language
display
Offline Maintain
 > Configuration > Display
ProLink II
ProLink
 > Configuration > Display > Display Options
ProLink III
Device Tools
 > Configuration > Transmitter Display > Display Security
Field Communicator Configure > Manual Setup > Display > Offline Variable Menu Features
Overview
By default, access to the off-line menu of the display is enabled. If it is disabled, you must
enable it if you want to use the display to configure the transmitter.
Restriction
You cannot use the display to enable access to the off-line menu. You must make a connection from
another tool.
3.4
Disable write-protection on the transmitter
configuration
Display (standard)
OFF-LINE MAINT
 > CONFG > LOCK
Chinese-language
display
Offline Maintain
 > Configuration > Lock
ProLink II
ProLink
 > Configuration > Device > Enable Write Protection
ProLink III
Device Tools
 > Configuration > Write-Protection
Field Communicator Configure > Manual Setup > Info Parameters > Transmitter Info > Write Protect
Overview
If the transmitter is write-protected, the configuration is locked and you must unlock it
before you can change any configuration parameters. By default, the transmitter is not
write-protected.
Introduction to configuration and commissioning
Configuration and Use Manual 
19