Honeywell SMV 3000 Manual De Usuario

Descargar
Página de 217
34
SMV 3000 Transmitter User’s Manual 
1/99
4.5
Wiring SMV 3000 Transmitter,  
Continued
Wiring connections,
continued
Table 7
Wiring the Transmitter, Continued
Step
Action
7
Replace integral meter, if applicable; replace end-cap, and tighten
end-cap lock.
Figure 15
RTD Input Wiring Connections.
R
R
W
R
R
R
W
W
Keep Resistance 
of All Leads Low
2-Wire RTD Connections 
3-Wire RTD Connections 
4-Wire RTD Connections 
Keep Resistance 
of All Leads Equal
RTD 
W
TEST
SIG
+
+
METER L
SIGNAL
1
2
TC
3
4
+
+
TEST
SIG
+
+
METER L
SIGNAL
1
2
TC
3
4
+
+
TEST
SIG
+
+
METER L
SIGNAL
1
2
TC
3
4
+
+
Legend: 
R = Red 
W = White
Figure 16
Thermocouple Input Wiring Connections.
Thermocouple  Connections 
TEST
SIG
+
+
METER L
SIGNAL
1
2
TC
3
4
+
+
+
ATTENTION: If you use shielded 
cable, be sure the shield and 
transmitter housing reference 
ground at the same point. 
Continued on next page