24
Electrical Connections                                          
Before plugging in the water heater, always make sure:
•      The Voltage and frequency correspond to that specified on                                               
       the water heater.
•     The electrical outlet has the proper overload fuse or breaker  
       protection.
•      Unit is to connect to a 120VAC electrical supply outlet      
       (extension cord is not allowed).
WARNING
Electric Shock Hazard
Disconnect power before 
servicing.
Replace all parts and panels 
before operating.
Failure to do so can result in
death or electrical shock.
 
Pressure 
Switch
Control Display
Power Supply
Transformer
Igniter/Flame
Sense Connector
Air Intake
Chamber Fan
Anode
Rod
Gas Control 
Valve / Thermostat
CAUTION:
LABEL ALL WIRES PRIOR TO 
DISCONNECTION WHEN SERVICING 
CONTROLS. WIRING ERRORS CAN CAUSE 
IMPROPER AND DANGEROUS OPERATION. 
VERIFY PROPER OPERATION AFTER SERVICING.
FV
Sensor
CAUTION:
 
DO NOT USE AN EXTENSION 
CORD TO CONNECT THE 
TRANSFORMER TO AN 
ELECTRICAL OUTLET.
Wiring Diagram
IMPORTANT: Do not use an extension cord to connect the water 
heater to an electrical outlet.
• 
The water heater and the outlet are properly grounded.
•     Installed in accordance with prevailing provisions of    
 
       local codes, or in the absence of such, National Electric    
       Code, ANSI/NFPS 70 current edition.
Completely fill the tank with water and check all connections for 
leaks. Open the nearest hot water faucet and let it run for three (3) 
minutes to purge the water lines of air and sediment and to ensure 
complete filling of the tank. The electrical power may then be 
turned on. Verify proper operation after servicing.
ELECTRICAL
Solar Installation                                                   
If this water heater is used as a solar storage heater or as a 
backup for the solar system, the water supply temperatures to 
the water heater tank may be in excess of 120°F. A mixing valve 
or other temperature limiting valve must be installed in the water 
supply line to limit the supply temperature to 120°F.
NOTE: Solar water heating systems can often supply water with 
temperatures exceeding 180°F and may result in water heater 
malfunction.
FIGURE 27.