Build Opening Clearances (Fig 1) 
 
Table 1 
 Minimum Installation Clearances 
Reference Description 
Minimum Distance 
in Inches (cm) 
Vertically below a window, door which opens, air inlet 
12” (30.5 cm) 
Vertically above a window, door which opens, air inlet 
12” (30.5 cm) 
Below eaves, porches, or overhangs 
36” (91.4 cm) 
Horizontally from a window, door which opens, air inlet 
12” (30.5 cm) 
Horizontal distance from another water heater 
2” (5.1 cm) 
Vertical distance from another water heater 
12 (30.5 cm) 
 
REMOVE CARTON 
 
Move water heater to a location near where it will be installed.  Carefully slide water heater out 
from the carton and remove all the contents
 
MOUNT WATER HEATER ON THE WALL 
 
The EVERHOT
® IGE series water heater must be installed outdoors.  Refer to Table 1 
clearances under overhangs, windows, doors, etc.  Also avoid locations where there is heavy 
water runoff from roofs.  Determine the proper height and location for the water heater to be 
installed.  Consider the water and gas connections.  Allow enough room for servicing the water 
heater and maintain the clearances from combustible materials previously stated.  The water 
heater is supported on the wall by means of a top and bottom slotted angle bracket.  For 
convenience, the center hole of the bracket is slotted so that a center screw may be first installed 
in the wall for hanging the water heater on the wall.  Two more screws are then added on the 
ends of the bracket to secure the water heater.  Wall anchors should be used for the bracket 
holes unless the bracket lines up with a stud.  As an alternative, a suitable piece of plywood or 
2x4 wooden support may be cut to span the wall studs and the brackets.  Make sure the anchors 
are rated to support the 50 pound (23 kg) weight of the water heater. 
 
 
10