Bradford-White Corp IGE-199R Series Manual De Usuario

Descargar
Página de 44
SECTION V:  WATER CONNECTIONS 
 
 
WARNING
 
Failure to install and maintain a new, listed pressure relief valve will release the manufacturer from any 
claim, which might result from excessive temperature and pressures. 
Keep clear of the pressure relief valve discharge line outlet.  The discharge may be hot enough to cause 
scald injury.  The water is under pressure and may splash. 
 
 
WARNING
 
DO NOT reverse the inlet and outlet (cold and hot water) connections on the water heater.  This may 
cause a hazardous operating condition or the water heater may be inoperable 
 
WATER QUALITY 
 
The EVERHOT
® water heater must have the water quality within the following limits for long life and 
reliable operation (see Table 2).  The water supply should be tested to make sure the quality is within the 
specified limits.  If there is a problem with the water quality, contact your local water conditioning company 
for equipment to condition the water supply to this appliance.   
 
NOTICE
 
Operating this water heater with water conditions outside the specified limits will void the warranty. 
 
Table 2 
Description 
pH 
TDS 
(Total 
Dissolved 
Solids) 
Total 
Hardness 
Aluminum Chlorides  Copper 
Iron  Manganese  Zinc 
Levels 
6.5 to 
8.5 
Up to 500 
ppm 
Up to 
200 ppm 
or 11.7 
grains of 
hardness 
Up to 0.2 
ppm 
Up to 
250 ppm 
Up to 
1.0 ppm 
Up to 
0.3 
ppm 
Up to 0.05 
ppm 
Up to 
5 ppm 
 
Lime Condition Warning Signal: 
 
If the EVERHOT water heater is operated under hard water conditions without a water conditioner, the 
error code “LC” may flash on the remote temperature display.  This code means the heat exchanger coil 
is beginning to accumulate scale deposits and MUST be flushed (see Section IX, “Flushing Procedure for 
Lime Scale Removal…”).  Contact your installer for a qualified service technician to flush the heat 
exchanger.  A water conditioner may be needed to prevent this condition from reoccurring.   
 
NOTICE
 
Failure to flush the appliance when “LC” is flashing will cause damage to the heat exchanger.  Damage 
caused by lime or scale build up is not covered by the water heater warranty. 
 
INSTRUCTIONS FOR CONNECTIONS 
 
1.  BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY 
VALVE.  After shutting off the main water supply, open a faucet to relieve the water line pressure 
to prevent any water from leaking out of the pipes while making the water connections to the 
water heater.  The COLD water inlet and HOT water outlet are identified on the bottom casing of 
the water heater.  Make the proper plumbing connections between the water heater and the 
plumbing system to the house.  All soldering materials and piping must be compatible with 
potable water.  Unions should be installed on both the hot and cold water lines for future servicing 
and disconnection of the water heater.  Install a shut-off valve in the cold water supply line.   
 
11