Bradford-White Corp UTW450S60FR*N Manual De Usuario

Descargar
Página de 52
 Page 29 
Blower Testing (cont’d) 
Does blower
energize within
2 minutes? 
Disconnect pres-
sure switch tub-
ing from blower 
(see photo 3).
Connect manome-
ter to pressure tap 
of blower (see 
photo 3). 
Disconnect vent
system from top of 
blower and remove 
vent adapter (see 
photo 5). 
Does  blower
energize after 
2 minutes, run 
for 30 seconds 
and shut 
down? 
Disconnect 
cord set in 
photo 9. Is 
there 115VAC 
across termi-
nals shown in 
photo 11? 
Is there 
115VAC at
wall outlet?
Replace blower. 
Repair or replace 
power cord. 
Determine 
power source 
problem and 
correct. 
Is there 
115VAC 
across termi-
nals shown 
in photo 7?
Incorrect supply
voltage polarity.  
Reconnect cord set 
shown in photo 4. 
Is there 115VAC 
between blue wire 
and ground wire
(see photo 8).
Replace blower. 
Does cord set 
have electrical
continuity? 
Replace cord
set.
Replace gas 
control.
See pressure 
switch testing 
on page 25. 
With blower running and 
exhaust adapter removed 
from top of blower, is there 
a negative  pressure of –
2.15” to –2.30” W.C.
Blower OK. 
Is there 115VAC across blue
and green wires (see photo 8). 
Replace blower. 
Determine volt-
age problem and 
correct. 
Remove exhaust 
adapter 
Pressure tap. 
Pressure 
switch tubing 
Green ground 
wire 
Blue wire
Shown with pressure 
switch removed 
Blower Testing
Y Y 
Check power cord 
for damage. 
29