Blower Removal 
Step 1. 
Move the gas control power switch to the 
“OFF” position.
Step 2. 
Unplug the water heater from the wall out-
let.
Step 3.
Disconnect vent system
from exhaust adapter on top of blower. 
Step 4.  
Remove  exhaust  adapter 
from blower (blade screw driver) and retain for 
use on new blower.
Step 5. 
Remove dilution air clip from air in-
take boot and retain for use on new blower.  
Step 6. 
Unplug cord sets from blower. 
Step 7.  Remove the three blower 
mounting screws (1/4” nut driver). 
Step 8. Remove blower with gasket from water heater.
Blower Installation 
Step 9. 
Clean any debris from jacket head of 
water heater 
Step 10. Set new blower with gasket 
in place using locating pins on blower flange to line 
up with location holes in jacket head. Be sure not to
damage gasket.
Gas control power 
switch 
TTW (water heater) 
power cord 
Blower cord 
sets
Blower mount-
ing screws 
Remove exhaust 
adapter and retain
for use on new 
blower 
Remove dilution air 
clip and retain for 
use on new blower 
Locating pins on 
blower flange 
Pin location holes
in jacket head
Blower Replacement 