Bradford-White Corp 238-47878-00B 04/10 Manual De Usuario

Descargar
Página de 76
 
   
Diagnostic Codes 
   
 
 
 
-73-
 
LED Status 
Accessory Module 
Status 
Probable Cause 
None 
No LED. 
Power not on. 
1. No power at outlet. 
2. Transformer bad, replace 
transformer. 
3. Transformer wire harness not 
properly connected.  Check all wire 
connections. 
Green 
LED on continuously. 
Power on (no fault). 
n/a 
Red 
One flash and three 
second pause. 
Leak alarm fault.  
Inlet Shut-off valve 
open. 
Water heater tank leak. 
Red 
Two flashes and three 
second pause. 
Leak alarm fault.  
Inlet Shut-off valve 
closed. 
Water heater tank leak. 
Amber 
Four flashes and three 
second pause. 
Leak sensor 
malfunction. 
1. Leak Sensor resistor removed. 
2. Leak Sensor improperly 
connected to Accessory Module. 
Amber 
Five flashes and three 
second pause. 
Gas control missing / 
not connected. 
1. Wrong gas control wire harness 
was used. 
2. Accessory Module was not 
connected to gas control. 
Red 
LED strobe (quick 
flashes). 
Hardware error. 
Internal electronics failure, replace 
Accessory Module. 
 
Status Probable 
Cause 
Setback Control not on. 
1. No power at Setback Control or outlet. 
2. Transformer bad, replace transformer. 
3. Transformer wire harness not properly connected.  
Check all wire connections. 
Setback Control is showing 
“Conn” error. 
1. The Setback Control is not connected to the Accessory 
Module and/or the water heater gas control (at all). 
2. The Setback Control wire harness has some wrong 
connections.  Replace the wire harness. 
 
 
NOTICE 
The leak detection alarm can be muted.  Press the button on the front of the Accessory Module 
to mute this alarm for 1 day. 
CAUTION
 
Perform a cycle of the Test Mode on the Accessory Module on a regular basis.  Perform the 
cycle by depressing the “Mute” button on the Accessory Module for at least (7) seconds.  In the 
Test Mode, the Accessory Module will go through the following sequence: 
•  Inlet Shut-off Valve opened for (10) seconds with continuously shown Amber LED and 
the alarm on for the first second 
•  Inlet Shut-off Valve closed for (10) seconds with continuously shown Red LED with and 
Inlet Shut-off Valve installed (or flashing Red LED without Inlet Shut-off Valve). 
•  Inlet Shut-off Valve opened for (10) seconds with flashing Green LED.