Baldor iMN1800 Manual De Usuario

Descargar
Página de 48
2-16 Installation & Operation
MN1800
Leadwire Connection   
1
2
3
4
5
6
7
8
9
Female (D Sub)
2
3
4
5
6
7
8
9
Female (D Sub)
1
10
11
12
13
14
15
17
16
18
19
20
21
22
23
24
25
Color
Pin#
Description (2 Phase 25 pin pin to flying leads)
Red
1
(X) A+ Winding
Green
2
(X) A– Winding
Yellow
3
(X) B+ Winding
Orange 4
(X) 
B– Winding
Black
13
Ground
Blue
14
(Y) A+ Winding
Green
15
(Y) A– Winding
White
16
(Y) B+ Winding
Black
17
(Y) B– Winding
Use twisted pair wires.  Shield open at shell.
Color
Pin#
Description (2 Phase 9 pin to flying leads)
Red
1
(X) A+ Winding
Green
2
(X) A– Winding
Yellow
3
(X) B+ Winding
Orange 4
(X) 
B– Winding
Black
5
Ground
Blue
6
(Y) A+ Winding
Green
7
(Y) A– Winding
White
8
(Y) B+ Winding
Black
9
(Y) B– Winding
Use twisted pair wires.   Shield open at shell.
X–Axis Connections
Color
Pin#
Description
Red
1
A+ Winding
Green
2
A– Winding
Yellow
3
B+ Winding
Orange 4
B– Winding
Blue
5
C+ Winding
Green
6
C– Winding
White
7
D+ Winding
Black
8
D– Winding
Black
13
Ground
Use twisted pair wires.  
Shield open at shell.
Y–Axis Connections
Color
Pin#
Description
Red
14
A+ Winding
Green
15
A– Winding
Yellow
16
B+ Winding
Orange 17
B– Winding
Blue
18
C+ Winding
Green
19
C– Winding
White
20
D+ Winding
Black
21
D– Winding
Black
13
Ground
Use twisted pair wires.  
Shield open at shell.
LD9092A00 (4 Phase 25 pin pin to flying leads)
LD9074A00
LD9068A00
Positioning Stages
Unpacking
Observe the condition of the shipping container and report any damage immediately to
the commercial carrier that delivered your stage.  Carefully remove the positioning stage
from the shipping crate or box.  Inspect the stage and report any evidence of damage to
your local Baldor sales office or authorized distributor. Save the shipping container for
future transportation.
Handling and General Guidelines
Be sure to observe the following guidelines:
1.
Carefully set the positing stage in place.    Do not drop a positioning stage onto
the mounting surface or machine base as this can result in internal damage to
bearing and drive components.
2.
Do not drill holes in a positing stage.  Contact Baldor if holes must be added.
3.
Avoid impact loads such as hammering and punching which may cause internal
damage to bearing and drive components.
4.
Avoid submersion in liquids of all types.
5.
Do not disassemble the positioning stage as this may void the product warranty.
Stage Specifications Disclaimer
Positioning stage specifications are dependant on the three following variables:
Temperature:  Catalog specifications are measured at 25 degrees Celsius.
Measurements of performance at other temperatures may yield different measurements.
Minimum ambient operating temperature:  5 degrees Celsius.  Maximum ambient
operating temperature:  75 degrees Celsius.  The positioning stage can be modified by
Baldor to allow the unit to be operated at temperatures outside of this range.  Contact
Baldor for more information.
Point of measurement:  Catalog specifications are measured 25mm above the slide
mounting surface.  If measurements are taken from other relative locations, results may
be different from the catalog specifications.
Mounting surface:  Catalog specifications are measured with the positioning stage
supported under its entire length, fastened down (bolted) and is mounted to a machine
base that has a maximum flatness error of 0.0005”/ft.