Polycom 3725-70003-009F Manual De Usuario

Descargar
Página de 300
ReadiVoice Administration & Maintenance Guide
134
Proprietary & Confidential
  
Changing the Alarm Settings 
To change the default alarm settings: 
1
Establish a Telnet connection to the Sun server and log in as cnow. 
2
Change directory to /rahome/bin. 
3
Open the .odprocrc file for editing and locate the alarm section (
). 
4
Referring to 
change the values that you want to change, being 
careful not to change anything else in the file. 
5
Save and close the .odprocrc file. 
Figure 5-3
The alarm settings in the .odprocrc file 
[alarm]
system_id  =  01
check_mibs  =  0 
interval  =  900
sysmax_capacity  =  480
systreshold  =  80
brgmax_capacity_1  =  480
brgtreshold_1  =  80
brgmax_capacity_2  =  240
brgtreshold_2  =  80
[] // 
[alarm]
Table 5-4
Alarm section parameters of .odprocrc file 
Keyword
Description
system_id
Uniquely identifies your ReadiVoice system. Don’t change this number. 
check_mibs
Boolean. If this is set to 1, at each polling interval, the ra_monitor.pl 
script checks the MIB variables listed in the ra_monitor.mibs file and 
prints them to standard output (the terminal window in which it’s running). 
interval
Interval in seconds between polling for alarms. The default value of 900 
(15 minutes) works well for large or busy systems. For a single-bridge or 
moderately busy system, you can reduce this to 500 – 700 seconds. 
For short-term testing or troubleshooting purposes, you can set this 
value to less than 20 seconds; but, you may notice that the ReadiVoice 
system slows down at this setting.
sysmax_capacity 
Maximum capacity (number of ports) of your system. Don’t change this 
number. 
brgmax_capacity
Maximum capacity (number of ports) of an individual bridge. Don’t 
change this number.