Polycom 3725-70003-009F Manual De Usuario

Descargar
Página de 300
ReadiVoice Administration & Maintenance Guide
150
Proprietary & Confidential
  
When you run the diagnose utility: 
1
The bridge you’re testing calls you at the number you specified, using the 
first bridge resource to be tested. 
2
When you answer the call, the bridge plays three numbers that identify 
the card, span, and channel on which the call is being made. 
In an IP system, the bridge plays a single number indicating the card on 
which the call is being made. 
3
When you hang up, the bridge calls you on the next resource to be tested 
and repeats the process until it completes the test. 
4
For each test call completed, the utility writes a line to a log file. 
The log file is specified in the diagnosticlogfile parameter of the 
.odprocrc file. The default setting is: 
diagnosticlogfile = /rahome/bin/TTU.log 
If this file exists, the utility appends the new test call records to it. 
Otherwise, it creates the file, adds a heading, and writes the records.
To start dial-out testing: 
1
Open a Telnet session to the CACS as user cnow, and switch user to root. 
2
Change to the /rahome/utils directory. 
3
Type ./diagnose and press 
ENTER
You see:
4
Type the ID of the bridge and press 
ENTER
. To find bridge IDs, go to the 
Bridges page in System Administration (see 
You see:
5
Enter the telephone number at which you want the bridge to call you 
exactly as it should be dialed. Type only the digits, with no parentheses 
or dashes, and then press 
ENTER
You see:
To quit, press ’q’:
To Go To Previous Step, Press ’p’:
Enter the ID of the Bridge to Test:
Enter the Phone Number to Dial Out To:
Enter Range of Cards:
From: