3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
4-20
C
HAPTER
 4: I
NSTALLING
 
AND
 C
ONNECTING
 C
ORE
B
UILDER
 M
ODULES
If power cord(s) WERE NOT supplied with the unit, choose a cord based 
on the following information: 
For units installed in the USA or Canada: Select a flexible, 
three-conductor power cord that is UL-listed and CSA-certified, with 
individual conductor wire size of #18 AWG, and with a maximum 
length of 4.5 meters. The power cord terminations should be NEMA 
Type 5-15P (three-prong earthing) at one end and IEC appliance inlet 
coupler at the other end.
Any of the following types are acceptable: SV, SVE, SVO, SVT, SVTO, 
SVTOO, S, SE, SO, SOO, ST, STO, STOO, SJ, SJE, SJO, SJOO, SJT, 
SJTOO, SP-3, SPE-3, SPT-3, G, W.
For units installed in all other countries: Select only a flexible, 
three-conductor power cord, approved by the cognizant safety 
organization of your country. The power cord must be of the type 
HAR (Harmonized), with an individual conductor wire size of 0.75 
sq.mm. The power cord terminations should be a suitably-rated 
earthing-type plug at one end and an IEC appliance inlet coupler at 
the other end. Both of the power cord terminations must carry the 
certification label (mark) of the cognizant safety organization of your 
country.
Plugging in the Unit
To plug in the unit:
Plug the power cord into the power source.
Plug the other end of the cord into the AC inlet located in the topmost 
section of the CoreBuilder 7000 family ATM switch front panel. Make 
sure the power cord is fully seated. A green power LED on the power 
supply should be lit. The unit is automatically powered up when the 
power cord is plugged in.
Make sure the fans are working. If the fans are not working, unplug the