3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
5-2
C
HAPTER
 5: P
OWER
-O
N
System States
This section describes the different system states of the 8-Port Board and 
how they are indicated on the LED display. 
The system states are:
Power-on
Normal operation
Hardware fault
Software fault
No power to unit
System States and
Switching Module
LEDs
LED indicators are located on the front panels of the CoreBuilder 7000, its 
power supply, switching modules, and interface modules. These LEDs 
indicate the current system state of the CoreBuilder unit and its 
components. Front panel LEDs can be extremely useful in determining the 
cause of specific problems.
The system state in which the CoreBuilder 7000 unit is currently 
operating is displayed by the switching module system status LEDs. 
Referring to Figure 5-1, these are the three LEDs: PWR, FAIL, and ACT(ive) 
on the left side of the LED panel. Table 5-1 shows the correlation 
between the current system state and SYS LEDs display. For example, 
during normal operation the PWR LED is on, the FAIL LED is off and the 
ACT LED is flashing. The LEDs on the right side of the panel indicate the 
status of the Ethernet port, the Service port and the Control port.
Figure 5-1   Switching Module LEDs
Control
1 0 B A S E - T
Status
S e r v i c e
Status
Status
P W R
A C T
F A I L