Redundant Power Supply
7-5
Required Power
Supply for Various
CoreBuilder
Installations
Table 7-3, which is calculated from Table 7-2, shows the number of 
power supplies required (Single or Dual) for various CoreBuilder 7000 
installations. The first column describes the particular combination of 
cards installed and covers the most common applications. The second 
column shows the number of power supplies required if a redundant 
switch is not installed; the third column shows the number of power 
supplies required if a redundant switch is installed.
7608T Fast Ethernet interface card 
8TX Fast Ethernet ports
8 Fast Ethernet ports unoccupied
3C37617
15.3
7662T Fast Ethernet module 
2TX Fast Ethernet ports
14 Fast Ethernet ports unoccupied
3C37662
1.4
* The typical power consumption values represent typical traffic, load and line speed of the 
CoreBuilder and interface cards
Maximum power consumption of the cards is 10% higher 
than the typical values, and occurs when all card ports are working at full rate
† A redundant switch has the same power requirements as the active switch
Table 7-2   Typical Power Consumption of CoreBuilder 7000 Family Cards 
Table 7-3   Required Power Supply for Various Installations 
Cards Installed in CoreBuilder Chassis
No Redundant 
Switch 
Installed
Redundant 
Switch 
Installed
Data Center - High-density Fast Ethernet and ATM
CB7000 HD Switching Card
4 X CB7600F Fast Ethernet Interface Card
Dual 90A
Dual 90A
CB7000 HD Switching Card
4 X CB7600T Fast Ethernet Interface Card
Single 90A
Dual 90A
CB7000 HD Switching Card
3 X 7600F Fast Ethernet Interface Card
1 X 8-port ATM Interface Card
Single 90A
Dual 90A
CB7000 HD Switching Card
3 X 7600T Fast Ethernet Interface Card
1 X 8-port ATM Interface Card
Single 90A
Single 90A
Data Closet - Ethernet 
CB7000 Switching Card
4 X 7436 ATM Interface Card
Single 90A
Single 90A