3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
7-6
C
HAPTER
 7: R
EDUNDANCY
 
IN
 
THE
 C
ORE
B
UILDER
 7000 F
AMILY
 ATM S
WITCH
Providing
Redundancy for
Various Power Loads
This section describes when redundant switch cards and redundant 
power supplies can be used in a CoreBuilder switch.
In order to determine whether a redundant switch card and/or an 
redundant power supply can be used in a CoreBuilder switch, the total 
power consumption of all installed cards must be examined. According to 
the total power consumption, there are three possibilities, as the 
following examples illustrate:
Installation I: 
The total power consumption of a single switching card 
(that is, no redundant card installed) and all interface cards exceeds 90A. 
In this case, a Dual 90A supply is required so that the second power 
supply cannot be redundant. A redundant switch card can be installed. 
This “heavy load” installation is illustrated by the first example installation 
in Table 7-3
Installation II:
The total power consumption of two switching cards 
(i.e., redundant card installed) and all interface cards exceeds 90A but 
without the second switching card the consumption is less than 90A. In 
this case, either a redundant switch card or a redundant power supply 
can be installed, but not both. This “medium load” installation is 
illustrated by the second example installation in Table 7-3. 
Installation III: 
The total power consumption of two switching cards 
and all interface cards does not exceed 90A. In this case, both a 
redundant switch card and a redundant power supply can be installed. 
CB7000 Switching Card
3 X 7436 ATM Interface Cards
Single 90A
Single 90A
ATM Data Center with high-density Fast Ethernet
CB7000HD Switching Card
1 X 7600F ATM Interface Card
3*8 port ATM Interface Cards
Single 90A
Single 90A
CB7000HD Switching Card
1 X 7600T ATM Interface Card
3*8 port ATM Interface Cards
Single 90A
Single 90A
Other applications
CB7000 Switch Card
4 X 7262 Ethernet/ATM Interface Card
Single 90A
Single 90A
Table 7-3   Required Power Supply for Various Installations  (continued)