3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
Redundant Switching Module
7-9
Redundant 
Switching Module 
This section covers the following topics:
Need for a
Redundant Switching
Module
redundant switching module is a backup switching card that is capable 
of performing all the tasks of the currently active switching module 
should it fail. For this purpose, the redundant module’s data base is kept 
up-to-date with network parameters that are configured in the active 
switching module. 
The redundant switching module is a necessary requirement in a 
critical-mission network. When a switch module fails in such a network, 
loss of data and interruption in transmission must be kept to an absolute 
minimum. 
Identifying the Active
Switching Module
As the CoreBuilder 7000 boots, the first of the two switch modules to 
begin operating becomes the active switch module. 
Once the unit has booted, the active switch module can be identified by 
the LMA command (1) SYS (4) SWM:
 
or by the ACT LED as follows:
Active Switch: ACT LED flashes rapidly
Redundant Switch: ACT LED flashes once every 2 secs.
The redundancy feature works for any combination of the CoreBuilder 
7000 and CoreBuilder 7000HD switch modules installed in the chassis.
Conditions for
Switch-over to
Redundant module
The switch-over to the redundant module will occur in the following 
situations:
Removal of the main switching module from the chassis.
Malfunction of the main switching module.
Manual reboot of the CoreBuilder 7000 by LMA, Telnet (soft reboot) 
or Transcend NMS.