7-10
C
HAPTER
 7: R
EDUNDANCY
 
IN
 
THE
 C
ORE
B
UILDER
 7000 F
AMILY
 ATM S
WITCH
During the switch-over, the redundant switch reboots itself and comes up 
as the active one. A temporary dropping of all connections will occur 
during the switch-over. The connections are re-established after the 
switch-over process is complete.
Switching Module
Configuration
Database
Each switching module contains a configuration data base where the 
switch configuration data is stored. In order that the redundant switching 
module be ready to assume the role of the active switch, its configuration 
database is updated from the active switch. This occurs in the following 
situations:
When the switch is booted. 
When the switch configuration is changed. 
Not all of the configuration data is transferred from the active to the 
redundant switch. The data that was not transferred must be updated 
manually. The following table presents data which is transferred and data 
which must be updated manually (see “Setting up Switch Module 
Hardware Redundancy” on page 4-
7).
.
Table 7-6   Updating Configuration Database
Data Transferred from Active to 
Redundant Switch
Data to be Updated Manually in 
Redundant Switch
CoreBuilder 7000 IP address
LECS topology database (include: LES list 
and addresses, ELAN names, connection 
type)
NMS IP address
Static ATM addresses
Default gateway IP address
PVC configurations, UNI version, UNI 
profile, signaling.
LECS state
LECS order list database (SW Ver. 3.50 
and up)
LES state
CoreBuilder 7000 network prefix
Network prefix significant length
CoreBuilder 7000 active LECS address 
Built-in LES ATM addresses
Built-in LES names elanXXXX_Y (ELAN 
name)
NNI/UNI port setup