Tandberg Data 
Tape Drive Installation 
Tandberg LTO HH Installation and User Manual 
9 
 
Example: SCSI-ID = 2 
 
Table 3.1  Service Connector strap settings for SCSI-ID (Dark = Strap mounted) 
If the tape drive is the only device on the SCSI  bus, you do not need to do anything.  
The  tape  drive  will  be  recognized  automatically.  (All  Tandberg  Data  tape  drives  are  delivered  with 
SCSI-ID 2 as default.) 
If the tape drive is going to share the SCSI-bus with other devices, check the SCSI-ID numbers used 
by  the  other  devices,  then  set  the  drive’s  SCSI-ID  to  a  number  that  is  not  being  used  by  any of the 
other devices (remember the SCSI host adapter uses ID 7) 
3.8.2  SCSI-ID Selection Tandberg LTO HH External Tape 
Drive 
For  the  external  tabletops,  you will find the SCSI-ID setting thumb-wheel switch on the rear end of 
the unit box: 
 
Figure 3.5  Drive connectors, external tabletop model 
3.9 SCSI-bus Termination 
3.9.1  Termination in General 
A  SCSI-bus  is  susceptible  to  interference,  such  as  noise  from  electrical  motors  and  other 
electromagnetic  devices.  Also  due  to  the  speed  of  the  data  on  the  SCSI-bus,  it  is  of  outmost 
importance to terminate the SCSI-bus properly. “Termination” is used to define the ends of the SCSI-
bus. 
SCSI-ID Switch
 
SCSI-ID=0 
SCSI-ID=1 
SCSI-ID=2 (Default) 
SCSI-ID=3 
SCSI-ID=4 
SCSI-ID=5 
SCSI-ID=6 
SCSI-ID=7 
SCSI-ID=8 
SCSI-ID=9 
SCSI-ID=10 
SCSI-ID=11 
SCSI-ID=12 
SCSI-ID=13 
SCSI-ID=14 
SCSI-ID=15