Genelec 7050B Manual De Usuario

Descargar
Página de 6
.1 output channel of a 5.1-channel discrete 
surround sound source. 
Once all connections have been made, the 
subwoofer and main loudspeakers are ready 
to be powered up.
Positioning in the room
The placement of the subwoofer in the room 
affects the overall frequency response and 
sound level of the system dramatically, as at 
low frequencies the effects of the room are 
strong. Even a slight change in the subwoof-
er's location can make a marked difference in 
the frequency balance and often patient and 
methodical  experimentation  and  testing  is 
needed to find the optimum placement. The 
placement  will  affect  the  phase  difference 
between the main loudspeakers and the sub-
woofer and the bass roll-off rate. 
First  place  the  subwoofer  slightly  offset 
from  the  center  of  the  front  wall.  The  rec-
ommended distance to the wall is less than 
60 cm / 24" measured from the subwoofer's 
driver. This position gives increased acoustic 
loading (and SPL) due to the proximity of the 
front wall and floor. Cancellations from the 
front wall and floor are also avoided. Front 
wall cancellation for the 85 Hz high pass fil-
tered main speakers can be eliminated by 
placing them at least 110 cm / 43" away from 
the front wall (see Figure 2).
If the frequency balance does not seem  
right,  try  moving  the  subwoofer  slightly  to 
the left or right so that different room modes 
are  excited  at  different  levels.  Positioning 
the subwoofer close to a corner will boost 
the bass level at lower frequencies and may 
cause asymmetrical spatial imaging.
Although  the  7050B  is  magnetically 
shielded,  it  may  cause  colour  distortion  if 
placed near to very sensitive video loudspeak-
ers or computer displays. Move the subwoofer 
further away or try turning the driver side of 
the subwoofer away from the screen.
Minimum clearances to walls 
or other objects
Do not cover the driver side of the subwoofer 
or place the subwoofer so that there is less 
than 10 cm (4") of free space in front of the 
grille.
Make sure that the space underneath the 
subwoofer is clear from obstructions. Thick 
carpets may block the ventilation clearance 
needed for cooling the electronics. 
The reflex port side (opposite of the con-
nector  panel  side)  should  always  have  a 
clearance of at least 7,5 centimeters (3") to 
any objects to ensure proper functioning of 
the reflex port.
Flush mounting the subwoofer
If the subwoofer is flush mounted into a wall 
or a cabinet, it is important to ensure ampli-
fier cooling and unrestricted airflow from the 
reflex port. This can be done by making the 
recess 7,5 centimeters (3") wider than the 
subwoofer. Place the subwoofer into the right 
end of the recess with the driver side facing 
the room. This leaves sufficient 7,5 centime-
ters (3") of free space on the reflex port side. 
The height and depth of the recess should 
not be any bigger than is needed to fit the 
subwoofer flush with the wall surface. 
Sensitivity adjustment
The  subwoofer  requires  input  sensitivity 
alignment to the source to obtain a correctly 
balanced system. The input sensitivity con-
trol is located on the connector panel of the 
subwoofer. An input voltage of -6 dBu with a 
-6 dBu input sensitivity setting will produce 
100 dB SPL @ 1 m in free field.
Setting the phase control
Incorrect  phase  alignment  between  the 
main loudspeakers and subwoofer causes 
Figure 3. Recommended distances to
the front wall
Figure 1. 7050B's amplifier panel, connectors and controls.
Figure 2. XLR to RCA connector for 
unbalanced operation.