Lucent Technologies Release 7 Manual De Usuario

Descargar
Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1329
PPP-PT (Control LAN Packet/Port) 
9
tone receiver receive tones on another timeslot. The tones are looped through the 
ppp port.
Test failure indicates failure of the
CLAN (TN799) circuit pack
TDM Bus
Tone generator / tone receiver circuit pack
If the received tones:
Then:
Match the tones sent
The test passes
Do not match the tones sent
The test fails
Table 9-518.
TEST #1285 TDM Looparound Test 
Error 
Code
Test 
Result
Description/ Recommendation
1000
ABORT
The port is in use.
1. Determine port status (status clan-port UUCSSpp).
2. If port is idle, retry the TDM Looparound Test (#1285). 
3. If port is not idle, busyout the port (busyout port UUCSS).
1002
ABORT
No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals, up to 5 times.
1003
ABORT
No more tone receivers idle for use in this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS 
and reset board UUCSS).
2. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
Continued on next page