Lucent Technologies Release 7 Manual De Usuario

Descargar
Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-310
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)] 
9
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI 
circuit pack detects that Level 1 has been deactivated on the port. The 
aux data field contains one of the following values:
blank - this indicates that the Level 1 Status Inquiry failed.
32773 - this is a message from the BRI-LINE circuit pack indicating 
Level 1 has been deactivated.
Refer to the repair procedures for Test #621.
b. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, replace or 
reinsert the circuit pack.
c. This error occurs when the EPF Status Inquiry fails due to an overcurrent 
condition or when the BRI-LINE circuit pack detects that the EPF is in an 
over current condition. The aux data field contains one of the following 
values:
blank - this indicates that the EPF Status Inquiry failed due to an 
overcurrent condition.
40988 - this indicates that the BRI-LINE circuit pack has detected 
an overcurrent condition and has turned the EPF off.
Execute the Short Test Sequence and see the repair procedures for Test 
#622.
d. This error indicates that the circuit pack is having problems transmitting 
data to the Packet Bus, thus affecting the conveyance of signaling 
information over the D-channel. With Aux Data 46222, this error occurs 
3846(n)
TEI
None
3847(o)
0
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2.
Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value
used in the set options command.
Table 9-138.
ISDN-BRI Port Error Log Entries — Continued
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level 
BRI-PORT
Alarm Level 
ABRI-PORT
ATT-PORT
LGATE-PT
ATTE-PT
On/Off 
Board
Test to Clear 
Value
Continued on next page