DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-311
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)] 
9
when the Packet Bus transmit buffers overflow. This condition probably 
indicates a hardware problem. The BRI-PORT Alarm Level for the error 
with Aux Data 46222 is ‘‘MIN/WRN,’’ and the 
ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT Alarm Level is 
‘‘MAJ/MIN/WNR.’’ With Aux Data 0, this error occurs whenever the Packet 
Bus transmit FIFO buffers overflow. This condition can be caused by an 
on-board hardware problem as well as by problems on the Packet Bus 
that disrupt the BRI circuit pack’s ability to transmit data onto the Packet 
Bus. Use troubleshooting procedures for both on-board hardware 
problems and potential off-board Packet Bus problems. See the 
‘‘PKT-BUS (Packet Bus)’’ section in this chapter as well as 
 in 
Chapter 5, ‘‘Alarms, Errors, and 
Troubleshooting’’
 for more details on Packet Bus troubleshooting 
procedures. The BRI-PORT Alarm Level for the error with Aux Data 0 is 
‘‘MINOR,’’ and the ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT Alarm Level 
is ‘‘MAJOR.’’
e. This error occurs when the NPE Crosstalk Test (#617) fails. Run the Long 
Test Sequence and pay particular attention to the results of Test #617.
f. This error occurs when broadcast signaling links associated with this port 
have too much link establishment related traffic. This could occur if an 
endpoint on this port is sending link establishment traffic on a port level 
broadcast link or if there are Level 1 problems on the port. Check the error 
logs for Level 1 errors. If Level 1 problems exist, follow the repair 
procedures listed for test #621. Software will suspend activity to this port 
for 75 minutes when the port is alarmed due to this error (note that service 
suspension does not occur if the port is an 
ABRI-PORT/LGATE-PT/ATTE-PT/ATT-PORT). If this problem persists, 
replace the endpoint or endpoints associated with this port. If replacing 
the endpoints does not fix the problem, follow normal escalation 
procedures.
g. This error occurs when the port receives an invalid frame over the 
D-channel. When CRC errors exceed five within 15 minutes, the port is 
taken out of service for five seconds. If five more CRC errors are received 
within 15 minutes of the first set of five errors, the port is taken out of 
service for one minute. If five more CRC errors are received within 15 
minutes of the last five, the port is taken out of service for 15 minutes.
This error is most likely due to a problem with the wiring to the set or 
adjunct, interference on the wiring due to a noise source, or no termination 
(an open circuit). It usually does not indicate a problem with the circuit 
pack.
Check the wiring to the endpoints or the adjunct.
If the problem persists, replace the endpoints or adjuncts, or 
escalate the problem.
h. This error occurs when the BRI Port Local TDM Loop Around Test (#619) 
fails. Run the Long Test Sequence and pay particular attention to the 
results of Test #619.