2.7.3  battery cable connectIons
1.  Connect the battery cable from the battery post or 
terminal indicated by a POSITIVE, POS or (+) to 
the lug on the starter contactor (Figure 2.16).
NOTE:
Check  to  be  sure  the  battery  cable  boot  for  the 
starter cable has been installed.
2.  Connect  the  battery  cable  from  the  battery  post 
indicated  by  a  NEGATIVE,  NEG  or  (-)  to  the 
frame ground connection (Figure 2.16).
3.  Connect  cables  so  the  connectors  are  clean  
and tight.
Figure 2.16 – Connecting Battery Cables
342.2
[13 1/2"]
778.9
[30 11/16"]
REF.
FRONT DOOR ACCESS FOR
ALL REQUIRED MAINTENANCE
REMOTE PANEL
CONNECTOR
500.2
 [19 11/16"]
REF.
AC OUTPUT
HARNESS
HOT AIR
EXHAUST
TAIL PIPE
EXIT
OIL DRAIN
AIR
INTAKE
48.1
[1 7/8"]
222.7
[8 3/4"]
300.7
[11 13/16"]
369.7
[14 9/16"]
688.3
[27 1/8"]
29
[1 1/8"]
55.5
[2 3/16"]
376.5
[14 13/16"]
5/16"-18 WELDNUTS
(6 PLACES)
82.5
[3 1/4"]
343.4
[13 1/2"]
423.2
[16 11/16"]
717.7
[28 1/4"]
50.8
[2"]
118
[4 5/8"]
223.5
[8 13/16"]
60
[2 3/8"]
210
[8 1/4"]
176.6
[6 15/16"]
83.5
[3 5/16"]
429.5
[16 15/16"]
414.5
[16 5/16"]
360.5
[14 3/16"]
63.5
[2 1/2"]
416
[16 3/8"]
170
[6 11/16"]
79
[3 1/8"]
101
[4"]
TYP.
6.7
[1/4"]
736.4
[29"]
476.4
[18 3/4"]
36.5
[1 7/16"]
[1 7/16
[1 7/16
39.6
 [1 9/16"]
69.6
 [2 3/4"]
34.3
 [1 3/8"]
71.2
 [2 13/16"]
211.3
 [8 5/16"]
 NEG. BAT.
 CONNECTION
POS. BAT.
CONNECTION
 LP FUEL INLET
VIEW FROM TOP
NOTE: ALL AIR INTAKES AND EXHAUST OUTLETS MUST BE
      KEPT CLEAR OF ANY OBSTRUCTIONS.  ALL OPEN AREA
      IS REQUIRED FOR COOLING.
CONNECTIONS IN
BACK OF GENERATOR
2.7.4  battery coMpartMent
Install the generator battery in its own, vented com-
partment. Place the battery compartment away from 
any source of heat, sparks or flame.
Provide ventilation openings in the battery compart-
ment.  The  minimum  size  of  openings  should  be  2 
square inches at the top of the compartment. Mount 
the  battery  on  a  strong,  rigid  supporting  structure, 
where leaks and spills of battery fluid will not cause 
damage.
2.8   optIonal accessorIes
A  plug-in  receptacle  (Figure  2.17)  is  provided  on 
the  generator  set.  Use  this  receptacle  to  connect  an 
optional  remote-mounted  start/stop  panel  to  the 
generator.  Installation  of  such  a  panel  will  permit 
starting and stopping the generator engine from any 
convenient location inside the vehicle.
Figure 2.17 – Remote Panel Plug-in Receptacle
12.00"
14
0
17
15
18
14A
1
3
2
5
4
6
0
14
17
18
14A
15
15
17
14A
18
14
0
No.
WIRE
WIRE
COLOR
RED
YELLOW
ORANGE
WHITE
BLUE
BROWN
12.0 (305)
LENGTH (mm)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
FUNCTION
GROUND
ENGINE RUN SIGNAL
12 VDC
START
STOP
PRIME
P/N: 0D9099-B
2.8.1  reMote start/stop panel
A remote mounted Start/Stop panel (Figure 2.18) is 
available  that  allows  the  user  to  start  and  stop  the 
generator engine conveniently from inside the vehicle.  
The remote panel includes a Start/Stop switch, hour-
meter, generator run lamp, a fuel prime switch, and 
a  wire  harness.  The  hourmeter  should  be  used  in 
conjunction  with  the  maintenance  operations  found 
in Part I of this manual.
Figure 2.18 – Optional Remote Panel
PRIME
FUEL
STOP
RUN
section 2 – Installation
recreational vehicle generator