recreational vehicle generator
1.2  generator applIcabIlIty
These  generators  have  been  designed  and  manufac-
tured for supplying electrical power for recreational 
vehicles.  Do  not  modify  the  generator  or  use  it  for 
any application other than for what it was designed. 
If  there  are  any  questions  pertaining  to  its  applica-
tion, write or call the factory. Do not use the unit until 
advised by a competent authority.
danger
 
  For fire safety, the generator must have been 
properly installed in compliance with ANSI 
119.2-1975/NFPA 501C-1974, “Standard for 
Recreational Vehicles, Part III – Installation of 
Electrical Systems.” The generator also must 
have been installed in strict compliance with the 
manufacturer’s detailed installation instructions. 
After installation, do nothing that might ren-
der the unit in noncompliance with such codes, 
standards and instructions.
Use  this  generator  to  supply  electrical  power  for 
operating  120-volt,  single-phase,  60  Hertz,  AC  elec-
trical  loads.  These  loads  can  require  up  to  3,400 
watts (3.4 kW) of power, but cannot exceed 28.3 AC 
amperes of current at 120 volts.
 
  Do not overload the generator. Some installa-
tions may require that electrical loads be alter-
nated to avoid overloading. Applying excessive-
ly high electrical loads may damage the genera-
tor and may shorten its life. Add up the rated 
watts of all electrical lighting, appliance, tool 
and motor loads the generator will power at 
one time. This total should not be greater than 
the wattage capacity of the generator. If an 
electrical device nameplate gives only volts and 
amps, multiply volts times amps to obtain watts 
(volts x amps = watts). Some electric motors 
require more watts of power (or amps of cur-
rent) for starting than for continuous operation.
1.3   saFety
Before  attempting  to  use  the  generator  set,  care-
fully read the “Safety Rules” section of this manual. 
Comply strictly with these rules to prevent accidents 
and  damage  to  equipment  and/or  property.  We  sug-
gest copying and posting the “Safety Rules” in poten-
tial  hazard  areas  of  the  vehicle.  Stress  safety  to  all 
operators and potential operators of this equipment.
1.4    generator ac  
connectIon systeM
This  generator  set  is  equipped  with  dual  stator  AC 
power  windings.  These  two-stator  windings  sup-
ply  electrical  power  to  customer  electrical  loads  by 
means  of  a  two-wire  connection  system.  Note,  how-
ever,  that  the  neutral  is  bonded  to  the  frame  of  the 
engine-generator.
The generator may have been installed so that it pow-
ers 120-volt AC loads (Figure 1.1).
Figure 1.1 – Connections for 120 Volts Only
28.3 AMP
1.5   specIFIcatIons
1.5.1  Fuel requIreMents
These generators are equipped with a liquefied petro-
leum (LP) gas fuel system. LP gas is usually aupplied 
as a liquid in pressure tanks.
These  generators  require  a  “vapor  withdrawal”  type 
fuel system. This type of gaseous fuel system uses the 
vapors  forming  above  the  liquid  fuel  in  the  storage 
tank. Air temperature around the storage tank must 
be high enough to sustain adequate fuel vaporization. 
In colder climates, use of an independent heat source 
may be needed to be sure the fuel sufficiently vapor-
izes in the storage tank.
LP gas may consist of propane, butane, or a mixture 
of the two gases. Propane vaporizes at tempertures as 
low as -20°F (-29°C), but butane returns to its liquid 
state when the temperature drops below about 32°F 
(0°C).  For  that  reason,  a  higher  ratio  of  propane  is 
desired  in  the  gas  mixure  when  temperatures  drop 
below freezing.
1.5.2  Fuel consuMptIon
Fuel consumption is in gal/hr.
Model 
1/2 Load 
Full Load
 
004701-0 
0.55 
0.73