2.7.3 BATTERY CABLE CONNECTIONS
 
‹
1.  Connect the battery cable from the battery post or 
terminal indicated by a POSITIVE, POS or (+) to 
the lug on the starter contactor (Figure 2.16).
NOTE:
Check to be sure the battery cable boot for the 
starter cable has been installed.
2.  Connect the battery cable from the battery post 
indicated by a NEGATIVE, NEG or (-) to the 
frame ground connection (Figure 2.16).
3.  Connect cables so the connectors are clean and 
tight.
Figure 2.16 – Connecting Battery Cables
NEG
FUEL
POS
2.7.4 BATTERY 
COMPARTMENT
 
‹
Install the generator battery in its own, vented com-
partment. Place the battery compartment away from 
any source of heat, sparks or flame.
Provide ventilation openings in the battery compart-
ment. The minimum size of openings should be 2 
square inches at the top of the compartment. Mount 
the battery on a strong, rigid supporting structure, 
where leaks and spills of battery fluid will not cause 
damage.
 2.8   OPTIONAL ACCESSORIES
A plug-in receptacle (Figure 2.17) is provided on 
the generator set. Use this receptacle to connect an 
optional remote-mounted start/stop panel to the 
generator. Installation of such a panel will permit 
starting and stopping the generator engine from any 
convenient location inside the vehicle.
Figure 2.17 – Remote Panel Plug-in Receptacle
12.00"
14
0
17
15
18
14A
1
3
2
5
4
6
0
14
17
18
14A
15
15
17
14A
18
14
0
No.
WIRE
WIRE
COLOR
RED
YELLOW
ORANGE
WHITE
BLUE
BROWN
12.0 (305)
LENGTH (mm)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
FUNCTION
GROUND
ENGINE RUN SIGNAL
12 VDC
START
STOP
PRIME
P/N: 0D9099-B
2.8.1 REMOTE START/STOP PANEL
 
‹
A remote mounted Start/Stop panel (Figure 2.18) is 
available that allows the user to start and stop the 
generator engine conveniently from inside the vehicle.  
The remote panel includes a Start/Stop switch, hour-
meter, generator run lamp, a fuel prime switch, and 
a wire harness. The hourmeter should be used in 
conjunction with the maintenance operations found 
in Part I of this manual.
Figure 2.18 – Optional Remote Panel
PRIME
FUEL
STOP
RUN
Section 2 – Installation
Recreational Vehicle Generator