Yamaha 01V96i Manual De Usuario

Descargar
Página de 186
12
Analog I/O & Digital I/O
01V96i—Reference Manual
Analog I/O & 
Digital I/O
This chapter describes the 01V96i’s analog and digital 
input/output connectors as well as the basic operations 
involving the digital I/Os.
Analog Inputs & Outputs
Input Section
The 01V96i’s top panel features input connectors, which 
enable you to connect microphone and line-level sources. 
• INPUT connectors A 1–12
These balanced TRS-type 
phone connectors accept 
line-level and microphone sig-
nals. The nominal input range is 
–60 dB through +4 dB. The phantom [+48V] switches on 
the rear panel turn on or off the +48V phantom power 
feed to these inputs.
• INPUT connectors B 1–12
These balanced TRS-type con-
nectors accept line-level and 
microphone signals. The nominal input range is –60 dB 
through +4 dB.
You cannot use same-numbered INPUT A and INPUT B 
connectors simultaneously. (For example, you cannot use 
INPUT A-2 and INPUT B-2 at the same time.) If you 
connect cables to A and B connectors of the same num-
ber, only the signal from INPUT B is effective (e.g., B-2 
takes priority over A-2).
• INPUT  connectors  13–16
These balanced TRS-type phone con-
nectors accept line-level signals. When 
the AD 15/16 source selector is turned 
on (pushed in), signals from INPUT 15 
and 16 are ignored. Instead, signals from 
the 2TR IN connector will be routed to AD Input Chan-
nels 15 and 16.
• INSERT I/O connectors
These TRS-type phone connectors 
are used to insert external devices, 
such as effects processors, into AD Input Channels.
• Phantom  Power
Inputs 1 through 
12 feature switch-
able +48V phantom powering for use with con-
denser-type microphones and direct boxes. The phantom 
[+48V] switches on the rear panel turn on or off the +48V 
phantom power feed to the corresponding inputs.
• PAD  switches
Inputs 1 through 12 feature pad 
switches, which attenuate input 
signals by 20 dB. These switches 
are effective on both INPUT A and B signals.
• GAIN  controls
Inputs 1 through 16 feature 
rotary gain controls that adjust 
input sensitivity. Input sensitivity 
for INPUT connectors 1–12 
ranges from –16 dB to –60 dB when the Pad is off, and 
from +4 dB to –40 dB when the Pad is on. Input sensitiv-
ity for INPUT connectors 13–16 ranges from +4 dB to 
–26 dB.
• PEAK  &  SIGNAL  Indicators
The SIGNAL indicator lights up 
when the input signal level at 
INPUTs 1–16 exceeds –34 dB. 
The PEAK indicator lights up when the input signal level 
is 3 dB below clipping.
• 2TR  IN  connectors
These unbalanced RCA phono connec-
tors accept line-level signals from 
devices such as CD players.
When the AD 15/16 source selector is 
turned on (pushed in), signals input at 
these conductors are routed to AD 
Inputs 15 and 16. When the Monitor source selector is 
turned on (pushed in), you can monitor these signals 
from the MONITOR OUT connectors.
Tip: 
You can patch signals input from the INPUT connectors 
to any Input Channels. (See page 43 for information on 
patching input signals to Input Channels.)
A
A
2
1
B
B
INPUT
(BAL)
16
15
13
14
INSERT I/O
INSERT I/O
INSERT
OUT IN
(UNBAL)
20dB
PAD
20dB
GAIN
-16
-60
PEAK
SIGNAL
GAIN
L
R
IN
OUT
2TR
-10dBV 
(UNBAL)