Analog I/O & Digital I/O
01V96i—Reference Manual
Converting Sampling 
Rates of Signals Received 
at I/O Card Inputs
An optional MY8-AE96S Digital I/O card features sampling 
rate converters, so you can easily convert the sampling fre-
quency of digital inputs to the current 01V96i sampling rate.
1.
Press the DISPLAY ACCESS [DIO/SETUP] but-
ton repeatedly until the DIO/Setup | Format 
page appears.
Use the buttons in the SRC sections to turn the sampling 
rate converters on and off. You can turn the sampling rate 
converters of the digital I/O card on or off in pairs (odd & 
even channels, in this order).
2.
Use the cursor buttons to move the cursor to 
any two-channel button in the SRC sections, 
then press [ENTER].
The sampling rate converter for the selected 2-channel 
input turns on or off. When on, the sampling rate of the 
received digital audio is converted to the 01V96i’s current 
sampling rate.
Monitoring Digital Input 
Channel Status
You can view and monitor the Channel Status (sampling rate, 
emphasis, etc.) of digital audio signals connected to the 2TR 
Digital Inputs and Slot Inputs as follows.
1.
Press the DISPLAY ACCESS [UTILITY] button, 
then press the [F2] button.
The Utility | CH Status page appears.
On this page, use the following buttons to select a slot or 
connector for which you want to view the channel status.
1
2TR IN
This button enables you to view the Channel Status of 
input signals connected to the 2TR Digital Inputs.
2
SLOT
These buttons enable you to view the Channel Status of 
each two adjacent (odd and even, in this order) channel 
signals connected to the digital I/O card installed in the 
slot.
2.
Move the cursor to the desired input or slot 
button, then press [ENTER].
Channel Status information for the selected input is dis-
played. However, if a mini-YGDAI I/O card other than 
AES/EBU format is installed, Channel Status information 
will be grayed out. Channel Status information includes 
the following items:
3
FS
Indicates the sampling rate. If no signal is being input, or 
if the incoming wordclock is not synching to the internal 
clock, “Unlock” appears.
4
EMPHASIS
Indicates the Emphasis on/off status.
5
CATEGORY
Indicates the status of “Category Code Bit” included in 
the IEC958 Part 2 (S/PDIF-Consumer) format. This 
parameter can display the following values: 
Tip: 
The FS box on the Word Clock page displays the sam-
pling frequency at which the 01V96i is currently operating.
Note: 
The sampling rate converter is available only on the 
Yamaha MY8-AE96S Digital I/O card. If you have installed 
another type of I/O card in the slot, or if no card is installed 
in the 01V96i, the buttons in the SRC sections are disabled.
1
2
3
4
5
6