12. SPECIFICATIONS 
・ Under certain conditions, a photovoltaic module may produce more voltage and current than reported at Standard Test  
Conditions (STC). Refer to Section 690 of the National Electrical Code for guidance in series string sizing and choosing 
overcurrent protection. 
 
Module Specification 
 
Electrical Characteristics: @ STC 
Module Type 
KD315GX-LFB 
KD320GX-LFB 
 Pmax 
315W 
320W 
 Voc 
49.2V 
49.5V 
Isc 
8.50A 
8.60A 
 Vpm 
39.8V 
40.1V 
 Ipm 
7.92A 
7.99A 
Factory installed Bypass Diode 
Number 
4pcs. 
Series Fuse Rating
 
15A 
Thermal Characteristics: Temp. Coefficient 
Voc  (V/°C) 
[Voc  (%/°C)] 
-1.77×10 
-1 
[-0.36] 
-1.78×10 
-1 
[-0.36] 
I sc   (A/°C) 
[I sc   (%/°C)] 
5.10×10
-3 
[6.0×10
-2
5.16×10
-3 
[6.0×10
-2
Vpm (V/℃) 
[Vpm (%/℃)] 
-2.05×10
-1 
[-0.52] 
-2.06×10
-1 
[-0.51] 
Physical Characteristics:  
Length 
65.43
” (1662mm) 
Width 
51.97
” (1320mm) 
Depth 
1.81
” (46mm) 
Weight 
60.6 lb (27.5kg) 
Mounting Hole 
Diameter .35
”(9mm), Quantity 4 
Grounding Hole 
Diameter .28
”(7mm), Quantity 4 
Application Class 
Class A 
 
 
NOTES 
(1) The electrical characteristics are within +/-5% (UL verified 10% 
tolerance,  according  to  UL  1703)  of  the  installed  values  of  Pmax 
and  within  +/-10%  of  the  installed  values  of  Isc  and  Voc  under 
standard test conditions (irradiance of 1000W/m
2
, AM 1.5 spectrum, 
and a cell temperature of 25 deg C). 
(2)  See  module  specification  sheet  for  most  recent  electrical 
characteristics. 
(3)  See  module  drawing  for  mounting  and  grounding  holes 
locations. 
 
51.97"
43.31"
3.94"
3.94"
11.06"
3.94"
3.94"
A
A
B
B
MODULE DIMENSIONS
PERMISSIBLE CLAMPING RANGE
CLAMPING AREA
50.79"
SECTION B-B
SECTION A-A
50.24"
(0.87")
0.87"
GROUND HOLE 
MARKED
MOUNTING HOLE
φ0.35" [TYP.]
1.81"
1.81"
0.41"
0.47"
1.18"
1.18"
51.97"
65.43"
43.31"
11.06"
40.94"
WIRE
LENGTH
WIRE