Wear a NIOSH-approved respirator 
to avoid breathing arc fumes.
Stroke the area to be welded with the 
11. 
Electrode to ignite the arc.  Never tap 
the Electrode into the welding sur-
face to ignite the arc.  This damages 
its external coating on the Electrode 
which prevents oxygen in the air from 
coming into contact with the molten 
metal, causing it to oxidize.
Once the arc is ignited, tilt the Elec-
12. 
trode forward at an angle of approxi-
mately 30° and hold it at a distance 
from the welding object equal to the 
diameter of the Electrode.
NotE:
13. 
  If too much current is drawn 
from the Welder, the internal Thermal  
Overload Protector will activate.  The 
Yellow “Overheating” Light (5) will 
illuminate, and the Welder will auto-
matically shut off until it cools down.  
Please wait until the welder automati-
cally restarts after the yellow “over-
heating” light turns off.   
(See Figures B and c.)
When the weld is complete, lift the 
14. 
Electrode clearly away from any 
grounded object.  Then turn the 
Power Switch (16) 
oFF
(See Figure c.)
Unplug the Power Cord (17) from its 
15. 
electrical outlet.
Remove the Ground Clamp (9) from 
16. 
the workpiece it is clamped onto.  
Then remove the Electrode from the 
Electrode Holder (8). 
(See Figure a.)
Allow all components of the Welder 
17. 
to completely cool.  Then clean and 
store the Welder indoors out of reach 
of children and other unauthorized 
persons.
IMPORTANT:  Refer to the included 
18. 
“Weld Diagnoses” pamphlet for tips 
and suggestions regarding proper 
welding.
tIG torch operating Instructions
 
please Note:  the 
following 
instructions are for tig 
welding using the tig torch.
to prEVENt SErIouS 
INjurY aNd dEath:   
do not touch the tip of the 
torch when the welder is 
connected to power.  the 
torch will immediately 
activate when it is plugged in.  
the operator must carefully 
direct the torch whenever 
the welder is connected to 
power.  when the operator is 
not holding the torch, it must 
be sitting on a nonconductive, 
nonflammable surface. 
Feed the filler metal being
used into the arc with a 
properly insulated holder (not 
included). 
To use Tig Torch, first disconnect 
1. 
Electrode Holder (8).
Attach the welder’s Ground Clamp 
2. 
to a clean uncoated metal part of the 
workpiece near the welding location.
Close the Gas Flow Knob on the 
3. 
torch completely, turning it clockwise 
until it stops.  Turn the argon gas sup-
ply on.
hold the torch in a safe direction
4. 
plug the welder’s power cord into a 
daNGEr