Hitachi SJ300-037HFE Manual De Usuario

Descargar
Página de 289
SJ300 Inverter
T
roub
leshooting
and Maintenance
6–7
NOTE: If an EEPROM error (E08) occurs, be sure to confirm the parameter data values are 
still correct.
E23
Gate array error
An internal inverter error has occurred in commu-
nications between the CPU and gate array IC. 
E24
Phase failure detection
One of three lines of the 3-phase power is missing.
E30
IGBT error
When an instantaneous over-current condition 
occurs on any IGBT (output transistor) device, the 
inverter alarm trips. then it turns the outputs OFF 
in order to protect the circuitry.
E35
Thermistor
When a thermistor is connected to terminals [TH] 
and [CM1] and the inverter has sensed the temper-
ature is too high, the inverter trips and turns OFF 
the output.
E36
Brake error
When the inverter releases the brake and cannot 
detect whether the external brake is ON or OFF 
within the waiting time (set by parameter B024), 
the inverter trips and turns OFF the output to the 
motor.
––––
Under-voltage (brownout) 
with output shutoff
Due to low input voltage, the inverter turns its 
output OFF and tries to restart. If it fails to restart, 
then the alarm trips to record the under-voltage 
error event.
Automatic restart and phase 
loss
The inverter is restarting, due to an over-current, 
over-voltage, under-voltage, or a phase loss event. 
See parameter B001 setting in 
.
E6X
Expansion card #1
connection error
An error has occurred in an expansion card or at 
its connecting terminals. Please refer to the 
manual for the expansion card for additional 
details.
E7X
Expansion card #2
connection error
Error 
Code
Name
Probable Cause(s)