FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The purge switch does not activate
the gas solenoid, but gun trigger
closure in the MIG or pulse modes
does activate the solenoid.  The
LEDs are steady green on the
power source,  and wire drive unit.
1. Make certain the COLD
INCH/GAS PURGE switch is
operating properly.
2. Check for loose or faulty leeds
between COLD INCH/GAS
PURGE switch and the feedhead
board.  See wiring diagram.
1. If the COLD INCH/GAS PURGE
switch is operating correctly and
the associated leeds are OK.
The feedhead board may be
faulty.
The COLD INCH/GAS PURGE
switch does not turn on the wire
drive motor but gun trigger closure
in the MIG or Pulse modes does
activate the wire drive motor.
The LEDs are steady green on the
power source, and wire drive unit.
1. Make certain the COLD
INCH/GAS PURGE switch is
operating properly.
2. Check for loose or faulty leeds
between the COLD INCH/GAS
PURGE switch and the feedhead
board.  See wiring diagram.
1. If the COLD INCH/GAS PURGE
switch is operating correctly and
the associated leads are OK.
The feedhead board may be
faulty.
The  voltmeter  on  the  wire  feeder
does  not  function  properly  even
though  the  STATUS  LEDS  are
steady green.
1. Make  sure  the  DIP  switches  are
configured  correctly  for  the  weld-
ing  polarity  being  used.    See
Setting Dip Switches in the Wire
Drive 
in  the  Installation section
of this manual.
2. Check  the  #67  lead  on  the  wire
drive unit. Make sure it is connect-
ed to the motor gear box and also
the voltage sense PC board.
3.Check  the  work  sensing  leads  on
the  POWER  FEED®  25M  power
source.    Check  leads  #202  (Neg.
output  terminal)  and  #206  (pos.
output  terminal).    See  POWER
FEED®  25M  wiring  diagram.    If
external voltage sensing is utilized,
Check the #21 lead between the 4-
pin  receptacle  on  the  front  of  the
POWERWAVE®  and  the  work-
place.
1. Check leads #513 and #514 from
J85 on the feedhead board to the
voltage  sense  PC  board.  Verify
placement in proper cavities.
2. Perform  the  Voltage  Sense
3. The display board may be faulty.
4. The  feedhead  control  board  may
be faulty.
5. The  Control  Box  control  board
may be faulty.
TROUBLESHOOTING AND REPAIR
F-9
F-9
POWER FEED® 25M