FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The displays are blank (not lit).  The
wire  feeds  when  the  gun  trigger  is
activated.
1. Check for loose or faulty connec-
tions at plug on the display board,
to  plug  on  the  memory  board  to
the  plug  on  the  msp-4  board  to
the  plug  on  the  push-pull  daugh-
ter board to the feed head board.
1. Check  for  5VDC  at  J37  pins  2
and 10 on the display board.  If 5
VDC is present, then the display
board may be faulty.
2. If the 5VDC is low or not present,
check for loose or faulty connec-
tions in SPI circuit.  See machine
schematic.
3. The feedhead control board may
be faulty.
The dual procedure is not function-
al  when  using  the  remote  Dual
Procedure  switch.    The  STATUS
LEDs  are  steady  green  on  the
power source, and wire drive units.
1. Make certain the LED indicator on
the Dual Procedure Panel is in the
middle position.  This enables the
gun  remote  dual  procedure
switch.
1. Check  shielded  cable  lead  and
connections from J86 on PC BD
to MSP panel.  Check SPI cable
from MSP panel to Dual/memory
panel.  Per machine schematic.
2. Check  for  5VDC  at  J86  pins  2
and 10.  Check for 15VDC at J86
pins  1  and  10.    If  voltage  is  not
present  replace  feed  head.    If
leads  and  voltages  are  good
replace dual/memory panel.
TROUBLESHOOTING AND REPAIR
F-10
F-10
POWER FEED® 25M