OKI OL610EPS Manual De Usuario

Descargar
Página de 182
%3.3.8 Motor Assy
                                                                                                                                                
3.3.8 Motor Assy
(1) Remove the upper cover (see 3.3.1).
(2) Remove the lower base unit (see 3.3.7).
(3) Stand the lower base unit on its left side as shown. Free the pulse and main motor cables from the 
lower base unit at location 3, , and unlock two clamp levers 2; then remove the motor assy 1.
Note: 
Use special care, because the idle gears and the reduction gear are 
not 
permanently attached and 
will become loose.
                                                                                                                                                
OKI OL600/610ex (96-01-18