Nilfisk-Advance America P 130.2 Manual De Usuario

Descargar
Página de 20
14
Nilfisk P 130.2 / P 150.2 / P 160.2
EN
WARNING! Always disconnect 
the electrical plug from the 
socket prior to maintenance or 
cleaning. 
To ensure a long and problem 
free working life, please take 
the following advice:
 Wash off water hose, high 
pressure hose, spray lance 
and accessories before 
mounting.
 Clean the connectors of dust 
and sand. 
 Clean the nozzles.
Any repair should always be 
made in an  authorized work-
shop with original spare parts.
7 Maintenance 
7.1  Cleaning of water inlet  
fi lter
Clean the water inlet fi lter regu-
larly once a month or more fre-
quently according to use. Care-
fully loosen the fi lter with a pair 
of pliers and clean it. Check that 
it is intact before re-mounting it. 
The inlet fi lter must always be 
fi tted inside the water inlet pipe 
to fi lter out sand, limestone and 
other impurities, as they will 
damage the pump valves.
CAUTION: Failure to fi t the fi lter 
will invalidate the guarantee.
7.2  Cleaning of nozzle 
A clogging up in the nozzle 
causes a pump pressure which 
is too high. This is why cleaning 
is required immediately.
 
1. Stop the machine and dis-
connect the  nozzle. 
2. Clean the nozzle. IMPOR-
TANT: The cleaning tool (11) 
should only be used when 
the nozzle is detached!
3. Flush the nozzle backwards 
with water.
7.3  Cleaning of machine  
vents
The machine should be kept 
clean so as to let cooling air 
7.4  Greasing of couplings
 
To ensure easy connection and 
that o-rings do not dry up, the 
pass freely through the ma-
chine vents.
couplings should be greased 
regularly.