Toshiba MA-516-100 Manual De Usuario

Descargar
Página de 166
- 38 -
EO1-11116
MA-516-100 SERIES
→
LOG
RECEIPT
LOG
RECEIPT
Extinguished
Illuminated
Receipt ON Status
Receipt OFF Status
NOTES
1. The Control Lock may be in any position (except OFF position) for changing the Receipt ON/
OFF status in the signed-ON or signed-OFF condition.
2. The “R OFF” lamp status at the starting of a transaction entry decides whether a receipt will
be issued for the transaction or not. Switching the Receipt ON/OFF status during a
transaction will not be effective.
3. If a transaction entered with the “R OFF” lamp illuminated and finalized but a receipt is
required, the [RECEIPT ISSUE] (Post-issue Receipt) key can be operated to issue a receipt
(see  “Post-issue Receipt” on page 92).
4. Simply depress the [LOG/RECEIPT] key without a numeric entry. If the key is depressed
with a prior numeric entry in “REG”, “MGR”, or “  - ” mode, it may turn out to be a Sign ON
or Sign OFF operation when the Singing Method is selected for cashier identification (refer
to the preceding chapter). However, if any Declaration Key (such as [RTN MDSE]) is already
pressed and then the [LOG/RECEIPT] key is pressed, the Declaration Key entry is not
canceled by the Receipt ON/OFF status change.
.....
.....
←
Receipts are issued or not issued according to the “R OFF” lamp illuminated/extinguished status on the Operator’s
Display panel.
“R OFF” (Receipts OFF) Lamp Status Change Operations
Control Lock may be in any position except OFF.
This chapter describes individual key operations on transaction entries, and setting requirements for the key if necessary.
WARNING!
When opening the cash drawer, be careful not to let the drawer hit any person.