Cisco Systems 1552H Manual De Usuario

Descargar
Página de 164
 
2-50
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-24247-01
Chapter 2      Installing the Access Point
  Powering the Access Point
Table 2-4
AC Power Cord Information
When using a user-supplied AC power plug on the AIR-CORD-R3P-40UE= power cord, ensure that the 
plug is certified for outdoor use and that it has a minimum IP67 rating, such as Interpower 84131251 or 
Hubbell HBL316P6W (IEC/EN 60309) pin-and-sleeve type connectors. The European Union power 
cord plug pinouts are listed in 
. For the location of the AC power connectors, see 
and 
.
Figure 2-37
European Union Plug Pinouts
Caution
All AC power plugs and AC receptacles must be protected from water and other outdoor elements. Use 
a UL listed waterproofing enclosure suitable for covering the AC receptacle and AC power plug that 
supplies power to the unit as described in Article 406 of the NEC. If the power cord goes through a metal 
cover, install a bushing to prevent fraying of the cord.
When using a strain relief bushing, you should follow these recommendations:
Use properly sized parts (see 
 for the power cord diameter)
Use bushings that are safety certified
Use parts that are suitable for outdoor installation
Caution
If your power cord does not use an AC power plug, you must ensure that the power source is OFF before 
connecting or disconnecting the power cord wires from the power source.
AC Power Cord
Cord Diameter
Comment
AIR-CORD-R3P-40NA=
0.398 to 0.413 in. 
(10.1 mm to 10.5 mm)
The three prong plug is limited to 120 VAC. 
Internal wiring is rated at 600 VAC insulation 
protection.
AIR-CORD-R3P-40UE=
0.398 to 0.413 in.(10.1 mm 
to 10.5 mm)
Power cord rating is 100 to 480 VAC. Internal 
wiring is 16 AWG.
AIR-PWR-ST-LT-TAP=
Strain relief bushing not 
needed
Power cord rating is 100 to 480 VAC
Pin
Description
Conductor Color
Pin Description
Conductor Color
1
Ground
Green/Yellow
3
Neutral
Blue
2
Live
Brown
1
3
2
255269