Cisco Systems 15454M6DC Manual De Usuario

Descargar
Página de 458
 
6-6
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 6      Circuits and Tunnels
Creating Circuits and VT Tunnels
Procedure: Create a Manually Routed Circuit
Note
If you want to route circuits on protected drops, create the card protection groups before creating 
circuits. See th
Step 1
Log into an ONS 15454 and click the Circuits tab. 
Tip
You can also right-click a source node in network view, select Provision Circuit To, and choose the 
circuit destination node from the menu.
Step 2
Click Create.
Step 3
In the Circuit Creation dialog box (
), complete the following fields: 
Name—(optional) Assign a name to the circuit. The name can be alphanumeric and up to 32 
characters (including spaces). If you leave the Name field blank, CTC assigns a default name to the 
circuit.
Type—Select the type of circuit you want to create: STS, VT (VT1.5), or VT tunnel. The circuit type 
determines the circuit-provisioning options that are displayed. 
 and the 
 for more information.
Size—Select the circuit size (STS circuits only). The “c” indicates concatenated STSs.
Bidirectional—Check this box to create a two-way circuit; uncheck it to create a one-way circuit 
(STS and VT circuits only; VT tunnels are bidirectional).
Number of circuits—Type the number of circuits you want to create. CTC returns to the Circuit 
Source page after you create each circuit until you finish creating the number of circuits specified 
here. 
Auto Ranged—This option is not available with manual circuit routing.
Protected Drops—If this box is checked, CTC only displays protected cards and ports (1:1, 1:N, 1+1 
or BLSR protection) as choices for the circuit source and destination. 
Figure 6-4
Creating a circuit
Step 4
(UPSR circuits only) Set the UPSR Selector Defaults: