Cypress CY8C24423 Manual De Usuario

Descargar
Página de 43
CY8C24123
CY8C24223, CY8C24423
Document Number: 38-12011  Rev. *G
Page 22 of 43
DC Switch Mode Pump Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C 
≤ T
A
 
≤ 85°C, or 3.0V to 3.6V and -40°C ≤ T
A
 
≤ 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only or unless otherwise specified.
Figure 11.  Basic Switch Mode Pump Circuit
Table 19.  DC Switch Mode Pump (SMP) Specifications
Symbol
Description
Min
Typ
Max
Units
Notes
V
PUMP 
5V
5V Output voltage
4.75
5.0
5.25
V
Average, neglecting ripple
V
PUMP 
3V
3V Output voltage
3.00
3.25
3.60
V
Average, neglecting ripple
I
PUMP
Available Output Current
V
BAT 
= 1.5V, V
PUMP
 = 3.25V
V
BAT 
= 1.8V, V
PUMP
 = 5.0V
8
5


mA
mA
For implementation, which 
includes 2 uH inductor, 1 uF cap, 
and Schottky diode
V
BAT
5V
Input Voltage Range from Battery
1.8
5.0
V
V
BAT
3V
Input Voltage Range from Battery
1.0
3.3
V
V
BATSTART
Minimum Input Voltage from Battery to 
Start Pump
1.1
V
ΔV
PUMP_Line
Line Regulation (over V
BAT
 range)
5
%V
O
a
a. V
O
 is the “Vdd Value for PUMP Trip” specified by the VM[2:0] setting in the DC POR and LVD Specification, 
ΔV
PUMP_Load
Load Regulation
5
%V
O
a
ΔV
PUMP_Ripple
Output Voltage Ripple (depends on 
cap/load)
25
mVpp
Configuration of note 2, load is 
5mA
Efficiency
35
50
%
Configuration of note 2, load is 
5mA, Vout is 3.25V.
F
PUMP
Switching Frequency
1.3
MHz
DC
PUMP
Switching Duty Cycle
50
%
Battery
C1
D1
+
PSoC
TM
Vdd
Vss
SMP
V
BAT