Page 25 of 34
AC SPI Specifications
The following table lists guaranteed maximum and minimum specifications for the entire voltage and temperature ranges.    
AC I
2
C Specifications
The following table lists guaranteed maximum and minimum specifications for the entire voltage and temperature ranges.  
Figure 13.  Definition for Timing for Fast/Standard Mode on the I
2
C Bus  
Table 31.   AC SPI Specifications
Symbol
Description
Conditions
Min
Typ
Max
Units
F
SPIM
Maximum Input Clock Frequency Selection, 
Master
 
2.4V<Vdd<5.5V
Output clock frequency is half 
of input clock rate.
12
MHz
Maximum Input Clock Frequency Selection, 
Master
(21)
1.71V<Vdd<2.4V
Output clock frequency is half 
of input clock rate
6
MHz
F
SPIS
Maximum Input Clock Frequency Selection, 
Slave 2.4<Vdd<5.5V
12
MHz
Maximum Input Clock Frequency Selection, 
Slave 1.71V<Vdd<2.4V
6
MHz
T
SS
Width of SS_ Negated Between Transmissions
50
ns
Table 32.   AC Characteristics of the I
2
C SDA and SCL Pins
Symbol
Description
Standard Mode Fast Mode
Units
Min
Max
Min
Max
F
SCLI2C
SCL Clock Frequency
0
100
0
400
kHz
T
HDSTAI2C
Hold Time (repeated) START Condition. After this period, the first clock pulse is 
generated.
4.0
0.6
μs
T
LOWI2C
LOW Period of the SCL Clock
4.7
1.3
μs
T
HIGHI2C
HIGH Period of the SCL Clock
4.0
0.6
μs
T
SUSTAI2C
Setup Time for a Repeated START Condition
4.7
0.6
μs
T
HDDATI2C
Data Hold Time
0
0
μs
T
SUDATI2C
Data Setup Time
250
100
ns
T
SUSTOI2C
Setup Time for STOP Condition
4.0
0.6
μs
T
BUFI2C
Bus Free Time Between a STOP and START Condition
4.7
1.3
μs
T
SPI2C
Pulse Width of spikes are suppressed by the input filter.
0
50
ns
SDA
SCL
S
Sr
S
P
T
BUFI2C
T
SPI2C
T
HDSTAI2C
T
SUSTOI2C
T
SUSTAI2C
T
LOWI2C
T
HIGHI2C
T
HDDATI2C
T
HDSTAI2C
T
SUDATI2C
Note
10. A Fast-Mode I2C-bus device can be used in a Standard Mode I2C-bus system, but the requirement t
SU;DAT
 
≥ 250 ns must then be met. This automatically be the case 
if the device does not stretch the LOW period of the SCL signal. If such device does stretch the LOW period of the SCL signal, it must output the next data bit to the 
SDA line t
rmax
 + t
SU;DAT
 = 1000 + 250 = 1250 ns (according to the Standard-Mode I2C-bus specification) before the SCL line is released.