Maximum Ratings
Exceeding the maximum ratings may impair the useful life of
the device. These user guidelines are not tested.
Storage Temperature  .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Supply Voltage to Ground Potential . –0.2V to V
CCmax 
+ 0.2V
DC Voltage Applied to Outputs
in High-Z State
........................... –0.2V to V
CCmax 
+ 0.2V
DC Input Voltage
........................–0.2V to V
CCmax
 + 0.2V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage..........................................  > 2001V
(MIL-STD-883, Method 3015)
Latch up Current..................................................... > 200 mA
Operating Range
Range
Ambient 
Temperature
V
CC
Industrial
–40°C to +85°C 
1.65V to 1.95V
DC Electrical Characteristics 
(Over the Operating Range)
Parameter
Description
Test Conditions
55 ns
Unit
Min
Typ
Max
V
OH
Output HIGH Voltage
I
OH
 = 
−0.1 mA
1.4
V
V
OL
Output LOW Voltage
I
OL
 = 0.1 mA
0.2
V
V
IH
Input HIGH Voltage
1.4
V
CC
 + 0.2
V
V
IL
Input LOW Voltage
–0.2
0.4
V
I
IX
Input Leakage Current
GND < V
I
 < V
CC
–1
+1
µA
I
OZ
Output Leakage Current
GND < V
O
 < V
CC
, Output Disabled
–1
+1
µA
I
CC
V
CC
 Operating Supply Current
f = f
MAX
 = 1/t
RC
V
CC
 = 1.95V, I
OUT
 = 0 mA, 
CMOS level
15
30
mA
f = 1 MHz
1.5
5
I
SB1
Automatic CE Power down 
Current 
− CMOS Inputs
CE
1
 > V
CC
 
− 0.2V, CE
2
 < 0.2V, 
V
IN
 > V
CC
 
− 0.2V, V
IN
 < 0.2V,
f = f
MAX
 (Address and Data Only), 
f = 0 (OE, WE, BHE and BLE)
2.5
20
µA
I
SB2
Automatic CE Power down 
Current 
− CMOS Inputs
CE
1
 > V
CC
 
− 0.2V, CE
2
 < 0.2V, 
V
IN
 > V
CC
 
− 0.2V or V
IN
 < 0.2V, 
f = 0, V
CC
=1.95V
2.5
20
µA
Notes
4. V
IL(min)
 = –2.0V for pulse durations less than 20 ns.
5. V
IH(max)
 = V
CC
 + 0.75V for pulse durations less than 20 ns.
6. Full device AC operation requires linear V
CC
 ramp from 0 to V
CC(min) 
and V
CC
 must be stable at V
CC(min)
 for 500
 µs.
7. Tested initially and after any design or process changes that may affect these parameters.
Capacitance 
Parameter
Description
Test Conditions
Max
Unit
C
IN
Input Capacitance
T
A
 = 25°C, f = 1 MHz, V
CC
 = V
CC(typ)
6
pF
C
OUT
Output Capacitance
8
pF