DC Programming Specifications
The following table lists the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C 
≤ T
A
 
≤ 85°C, or 3.0V to 3.6V and -40°C ≤ T
A
 
≤ 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only. 
Table 22.  DC Programming Specifications
Symbol
Description
Min
Typ
Max
Units
Notes
Vdd
IWRITE
Supply Voltage for Flash Write Operations
2.7
V
I
DDP
Supply Current During Programming or Verify
5
25
mA
V
ILP
Input Low Voltage During Programming or 
Verify
0.8
V
V
IHP
Input High Voltage During Programming or 
Verify
2.1
V
I
ILP
Input Current when Applying Vilp to P1[0] or 
P1[1] During Programming or Verify
0.2
mA
Driving internal pull down 
resistor
I
IHP
Input Current when Applying Vihp to P1[0] or 
P1[1] During Programming or Verify
1.5
mA
Driving internal pull down 
resistor
V
OLV
Output Low Voltage During Programming or 
Verify
Vss + 0.75
V
V
OHV
Output High Voltage During Programming or 
Verify
Vdd
 
- 1.0
Vdd
V
Flash
ENPB
Flash Endurance (per block)
50,000
Erase/write cycles per block
Flash
ENT
Flash Endurance (total)
1,800,000
Erase/write cycles
Flash
DR
Flash Data Retention
10
Years
Note
11. A maximum of 36 x 50,000 block endurance cycles is allowed. This may be balanced between operations on 36x1 blocks of 50,000 maximum cycles each, 36x2 blocks 
of 25,000 maximum cycles each, or 36x4 blocks of 12,500 maximum cycles each (to limit the total number of cycles to 36x50,000 and that no single block ever sees 
more than 50,000 cycles).
For the full industrial range, the user must employ a temperature sensor user module (FlashTemp) and feed the result to the temperature argument before writing. 