XG Series User's Guide
Chapter 3 Installation
Workflow for Initial Setup of the Device
57
3.1.1
Configure LAN Interface
The initial setting of the LAN interface is for only IPv6 link-local address.
To use the following functions, configure the LAN interface.
Telnet connection
SNMP manager connection
System log transmission
Time synchronization using an NTP/SNTP server
Configuration file upload/download
Firmware update
Collection of maintenance information
To configure the LAN interface, carry out the following procedure.
3.1.2
Telnet Connection via the LAN Interface (Optional)
The "Telnet server function" is initially enabled.
The telnet session timeout period is initially 5 minutes.
To change the telnet session timeout period, carry out the following procedure in "admin" Operation mode.
Command
Task
Login:admin
Password:
Login to the device from the serial terminal. The user name is
"admin". Type the password for uset "admin".
XG2600# configure
Switch to Configuration mode.
XG2600(config)# oob ip address A.B.C.D/M 3
Set the IP address, subnet, and default gateway of the LAN interface 
for management port. (XG2600 only)
XG2600(config)# lan 0 ip address A.B.C.D/M 3
XG2600(config)# lan 0 vlan 1
Set the IP address, subnet, and default gateway of the LAN interface 
for VLAN ID 1.
XG2600(config)# proxydns domain 0 any * any 
static A.B.C.D
(Optional)
Set up DNS servers.
XG2600(config)# commit
Apply the configuration.
XG2600(config)# save
Save the configuration.
XG2600(config)# exit
Switch to Operation mode.
Command
Task
XG2600# configure
Switch to Configuration mode.
XG2600(config)# telnetinfo autologout 30m
Set the Telnet session timeout period (30 minutes).
If the Telnet session timeout period expires the telne connection is 
terminated.
XG2600(config)# commit
Apply the configuration.
XG2600(config)# save
Save the configuration.
XG2600(config)# exit
Switch to Operation mode.