Lathem DDC4 Manual De Usuario

Descargar
Página de 63
DDC2 / 4-RS Wiring 
Digital Display Wall Clock Guide 
Page 42 
3-Wire Minute Impulse (44
th
 Minute) 
B
C
1 2
3 4
5
Clock must be set within 20 minutes of actual time 
for master to synchronize. Use of a 9Volt alkaline 
battery is recommended to avoid resets after power 
failures. 
OPEN
6 7
8
  Set switches 1-5 of S1 as shown. 
 
 Indicates depressed side of switch 
24VDC 
From 
Master Clock 
       To 
Other Clocks
A
BRN / WHT
GRND
AC IN
AC RTN
115VAC 
Local 
Power 
VIO / WHT
YEL / WHT
BLK
BLK
H
M