DDC2 / 4-RS -24 Wiring 
Digital Display Wall Clock Guide 
Page 44 
Appendix B - DDC2-RS-24 / DDC4-RS-24 Wiring 
The DDC2-RS-24 and the DDC4-RS-24 allow for 24VAC supplied from the Master Clock or Power 
Supply to power it for normal operation. These models can be used in installations where local 115VAC 
power may not be available. When shipped, the DDC2-RS-24 and DDC4-RS-24 have an optional power 
transformer that allows for 24VAC operation. 
 
The 24VAC power from the Master Clock or Power Supply should be connected to the two black wires 
leading from J1. (See figure 7 below for location of J1) 
 
Correction wiring should be applied according to the secondary type selection as shown in Appendix A. 
 
CAUTION: Applying any voltage higher than 24VAC to the input (two black leads 
from J1) WILL cause damage to the DDC2-RS-24 and DDC4-RS-24 clocks. 
JP2 
Fly Lead  
Connector 
 JP3 
JP1
Jumper 
J2 
Lathem Time Corp. 
   DDC2\4                   (E-PROM)
 
- + 
9VDC Alkaline Battery 
Cradle  
OPEN
1 2
3
4
5
6
7
8
DIP Switch 
S1
J1
  J4
  J3
JP4
Ground 
Beeper 
D- 
D+ 
Hours 
Minutes 
Up 
Down 
Figure 7