Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
OL-26701-02
Chapter 1      Preparing for Installation
Safety Guidelines
Preventing Electrostatic Discharge Damage
Many router components can be damaged by static electricity. Not exercising the proper electrostatic 
discharge (ESD) precautions can result in intermittent or complete component failures. To minimize the 
potential for ESD damage, always use an ESD-preventive antistatic wrist strap (or ankle strap) and 
ensure that it makes good skin contact.
Note
Check the resistance value of the ESD-preventive strap periodically. The measurement should be 
between 1 and 10 megohms.
Before you perform any procedure in this guide, attach an ESD-preventive strap to your wrist and 
connect the leash to the chassis as shown in 
Figure 1-3
Connecting an ESD-Preventive Wrist Strap to the Cisco ASR 9001 Router Chassis
Lifting Guidelines
A fully-configured Cisco ASR 9001 Router can weigh as much as 37.91 pounds (17.2 kg). These 
systems are not intended to be moved frequently. Before you install the router, ensure that you have 
planned the installation and migration of the router into your network so that you can avoid having to 
move the router later to accommodate power sources and network connections.
Use these lifting guidelines to avoid injury to yourself or damage to the equipment:
1
Location of chassis socket for ESD strap on the Cisco ASR 9001 Router
1