Cisco Systems 9001 Manual De Usuario

Descargar
Página de 114
4-8
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
OL-26701-02
Chapter 4      Troubleshooting the Installation
Troubleshooting the Power Subsystem
        host    1.8V_ZAR_LDO             1799   n/a
        host    3.3V_ZAR_LDO             3300   n/a
        host    2.5V_SKT_SKM             2500   n/a
        host    1.8V_LGTNG               1800   n/a
        host    1.5V_NP4C_1              1500   n/a
        host    1.5V_SKT                 1500   n/a
        host    1.05V_NP4C_CORE          1050   n/a
        host    1.0V_SKT                 1000   n/a
        host    1.0V_SKM                  999   n/a
        host    1.0V_LGTNG_CORE          1000   n/a
        host    0.9V_TCAM0_CORE           910   n/a
        host    0.9V_TCAM1_CORE           909   n/a
        host    3.3V_CLK_LDO             3299   n/a
        host    2.5V_CLK_LDO             2499   n/a
        host    1.2V_WL_LDO              1199   n/a
        host    1.0V_WL_LDO               999   n/a
        host    1.0V_PEX1                 992   n/a
        host    1.0V_PEX2                 999   n/a
        host    1.5V_NP4C2               1500   n/a
LED Information
---------------------------------------------
R/S/I   Modules LED             Status
0/RSP0/*
        host    Critical-Alarm  Off
        host    Major-Alarm     Off
        host    Minor-Alarm     Off
        host    ACO             Off
        host    Fail            Off
RP/0/RSP0/CPU0:ios#  
Troubleshooting the Power Distribution System
The power distribution system consists of:
AC or DC power modules that supply +12 VDC to the backplane.
Chassis backplane that carries voltage to chassis components.
DC-to-DC converters that convert +12 VDC from the backplane to the correct voltages required by 
the line card.
Use this procedure to troubleshoot the power distribution system:
Step 1
Check each power module to make sure that:
Power module is fully inserted and properly secured by its latch.
Green LED is on.
Amber LED is off.
If the power modules meet the above criteria, then the correct source power is present and within 
tolerance, and output DC power is present. The power modules are functioning properly.
Step 2
Make sure the fan tray is operating:
If the fan tray is functioning, then the +12 VDC from the chassis backplane to the fan tray is 
functioning properly.