13.7.3  Fundamental Parameters #1 
Parameter 
Function / Title Bank 
Mask  Adjustment Range 
Multiplier 
0026 
MAXIMUM OUTPUT 
FREQUENCY (*) 
0 / 1 
FFFF 
0BB8 
∼ 9C40 (30.00∼400.00) 
0.01 
0027 
BASE FREQUENCY #1 
0 / 1 
FFFF 
09C4 
∼ 9C40 (25.00∼400.00) 
0.01 
0028 
BASE FREQUENCY 
VOLTAGE SELECT (*) 
0 / 1 
0030 
0000: Input voltage level 
(0) 
0020: Automatic setting 
(1) 
0030: Stationary setting 
(2) 
 
0029 
MAXIMUM OUTPUT 
VOLTAGE #1 
0 / 1 
FFFF 
0000 
∼ 0258 (0 ∼ 600) 
002A 
REVERSE OPERATION 
DISABLE SELECT 
0 / 1 
0020 
0000: Reverse allowed 
(0) 
0020: Reverse not allowed 
(1) 
 
002B 
UPPER LIMIT FREQUENCY 
0 / 1 
FFFF 
0000 ~ Fmax 
0.01 
002C 
LOWER LIMIT FREQUENCY 
0 / 1 
FFFF 
0000 
∼ UL, Fmax 
0.01 
002D 
VOLTS PER HERTZ 
PATTERN (*) 
0 / 1 
000F 
0000: Constant torque 
(1) 
0001: Variable torque 
(2) 
0002: Auto. torque boost 
(3) 
0006: #3 w/ auto. energy savings  (4) 
000A: Vector control 
(5) 
000E: #5 w/ auto. energy savings  (6) 
 
002E 
1, 2 
VOLTAGE BOOST 
#1 
0 / 1 
FFFF 
0000 
∼ 012C (0.0 ∼ 30.0) 
0.1 
002F 
ACCELERATION TIME #1 
0 / 1 
FFFF 
0001 
∼ EA60 (0.01~ 600.00) 
0001 
∼ EA60 (0.1~ 6000.0) 
0.01 
0.1 
0030 
DECELERATION TIME #1 
0 / 1 
FFFF 
0001 
∼ EA60 (0.01~ 600.00) 
0001 
∼ EA60 (0.1~ 6000.0) 
0.01 
0.1 
0031 
ACC/DEC PATTERN #1 
SELECTION 
0 / 1 
0030 
0000: Linear 
(0) 
0010: Self-adjusting 
(1) 
0020: S-Pattern #1 
(2) 
0030: S-Pattern #2 
(3) 
 
0032 
ACCEL/DECEL PATTERN 
ADJUST LOW 
0 / 1 
00FF 
0003 ~ 00FD  (0 
∼ 50) (Note 1) 
0033 
ACCEL/DECEL PATTERN 
ADJUST HIGH 
0 / 1 
00FF 
0003 ~ 00FD  (0 
∼ 50) (Note 1) 
Note 1: 
Parameter data = (desired setting x 5 + 3), converted to hexadecimal